A Low-Cost Label-Free AFB1 Impedimetric Immunosensor Based on Functionalized CD-Trodes
نویسندگان
چکیده
This work describes the investigation of a label-free immunosensor for the detection of aflatoxin B1 (AFB1). CD-trodes (electrodes obtained from recordable compact disks) were used as low-cost and disposable transducers after modification with a self-assembled monolayer (SAM) of lipoic acid. The anti-aflatoxin B1 antibody was immobilized via EDC/NHS activation, followed by blocking with bovine serum albumin and immunoassays with AFB1. The optimization of analytical parameters and the detection were carried out using electrochemical impedance measurements. Using chemometric tools, the best conditions for the immunosensor development were defined as: anti-AFB1 antibody at 1:2000 dilution and surface blocking with 0.5% bovine serum albumin, both incubated for 1 h, and antibody–antigen immunoreaction for 30 min. The impedimetric immunosensor showed a linear range from 5 × 10−9 to 1 × 10−7 mol·L−1 (1.56–31.2 ng·mL−1), limit of detection and limit of quantification, respectively, 3.6 × 10−10 and 1.1 × 10−9mol·L−1 (0.11 and 0.34 ng·mL−1). The proposed immunosensor was applied to analyze peanut samples.
منابع مشابه
Application on Gold Nanoparticles-Dotted 4-Nitrophenylazo Graphene in a Label-Free Impedimetric Deoxynivalenol Immunosensor
In this paper, we report a new concept to construct a label-free electrochemical inhibition-based immunosensor for the detection of the mycotoxin deoxynivalenol (DON) in cereal samples. The electrochemical impedance spectroscopy of tris(bipyridine) ruthenium (II) chloride was used as a marker enhanced with gold nanoparticles-dotted 4-nitrophenylazo functionalized graphene (AuNp/G/PhNO2) nanocat...
متن کاملLabel-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria.
Here we describe the fabrication of a highly sensitive and label-free ITO-based impedimetric immunosensor for the detection of pathogenic bacteria Escherichia coli O157:H7. Anti-E. coli antibodies were immobilized onto ITO electrodes using a simple, robust and direct methodology. First, the covalent attachment of epoxysilane on the ITO surface was demonstrated by Atomic Force Microscopy and cyc...
متن کاملAn impedimetric immunosensor for the label-free detection of bisphenol A.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an a...
متن کاملImpedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A
An impedimetric label-free immunosensor on disposable screen-printed carbon electrodes (SPCE) for quantitative determination of Ochratoxin A (OTA) has been developed. After modification of the SPCE surface with gold nanoparticles (AuNPs), the anti-OTA was immobilized on the working electrode through a cysteamine layer. After each coating step, the modified surfaces were characterized by cyclic ...
متن کاملThe potentiality of the functionalized nitrogen and thiol-doped graphene quantum dots (GQDs-N-S) to stabilize the antibodies in the designing of human chorionic gonadotropin immunosensor
In this study, for the first time, a simple immunosensor for ultrasensitive recognition of Human Chorionic Gonadotropin (hCG) in serum samples was fabricated by exploiting a simple approach. In this method, a low-cost and sensitive immunosensor was fabricated based on QDs-N-S/Au nanoparticles (NPs) modified Screen-Printed Carbon Electrode (SPCE). It seems that, QDs-N-S/Au NPs/ antibody as a bio...