Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy.

نویسندگان

  • Y Kuang
  • A Hilgers
  • M Sadiq
  • S Cochran
  • G Corner
  • Z Huang
چکیده

Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of Ultrasound-Guided Dry Needling on Patients With Myofascial Pain Syndrome: A Review Study

Objectives: Dry Needling (DN) is a novel and effective intervention for patients with Myofascial Pain Syndrome (MPS). Some characteristics, such as needle penetration depth, needle insertion into the target muscle, and trigger points must be identified in this intervention. The Ultrasound (US)-guided DN is a technique that involves needle insertion at the site of injury and the simulation of ti...

متن کامل

Two-dimensional mapping to assess direction and magnitude of needle tip error in ultrasound-guided regional anaesthesia.

We assessed whether echogenic needles reduce tip location error, by comparing three echogenic designs (Pajunk Sonoplex, Lifetech, B. Braun Stimuplex D+) with a non-echogenic control (Pajunk Uniplex), using a novel assessment technique in unembalmed human cadavers. Multiple images were taken of each needle at shallow (15 to 25 degrees), moderate (35 to 45 degrees) and steep (55 to 65 degrees) in...

متن کامل

Ultrasound guidance for regional anaesthesia.

Editor—As a proponent of ultrasound-guided regional anaesthesia, I enjoyed reading the excellent case series by Karmakar and colleagues. 1 However, I have reservations about a number of the conclusions drawn in the accompanying editorial by Hopkins. 2 I agree that the recent regional anaesthesia ultrasound literature has many studies that lack equipoise. However, this fact surely reinforces our...

متن کامل

O-39: Ultrasound Deformable Model for Virtual Surgery Simulation of Oocyte Retrieval in Infertility Programs

Background The use of a medical simulator should enhance the goals of minimally invasive surgery: patient safety, cosmesis, shortening the length of hospital admissions, and reducing cost. Using an innovative approach to the handling of ultrasound images in virtual reality simulation, this article describes a process that employs a hybrid model of deformable models that can be applied in the te...

متن کامل

I-48: Ultrasound Deformable Model for Virtual Surgery Simulation of Oocyte Retrieval in Infertility Programs

Background The use of a medical simulator should enhance the goals of minimally invasive surgery: patient safety, cosmesis, shortening the length of hospital admissions, and reducing cost. Using an innovative approach to the handling of ultrasound images in virtual reality simulation, this article describes a process that employs a hybrid model of deformable models that can be applied in the te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasonics

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2016