Comparison of various detection limit estimates for volatile sulphur compounds by gas chromatography with pulsed flame photometric detection.

نویسندگان

  • Lionel J J Catalan
  • Victor Liang
  • Charles Q Jia
چکیده

This paper addresses the variations that presently exist regarding the definition, determination, and reporting of detection limits for volatile sulphur compounds by gas chromatography with pulsed flame photometric detection (GC-PFPD). Gas standards containing hydrogen sulphide (H(2)S), carbonyl sulphide (COS), sulphur dioxide (SO(2)), methyl mercaptan (CH(3)SH), dimethyl sulphide (DMS), carbon disulphide (CS(2)), and dimethyl disulphide (DMDS) in concentrations varying from 0.36ppb (v/v) up to 1.5ppm (v/v) in nitrogen were prepared with permeation tubes and introduced in the gas chromatograph using a 0.25-ml gas sampling loop. After measuring the PFPD response versus concentration, the method detection limit (MDL), the Hubaux-Vos detection limit (x(D)), the absolute instrument sensitivity (AIS), and the sulphur detectivity (D(s)) were determined for each sulphur compound. The results show that the MDL determined by the US Environmental Protection Agency procedure consistently underestimates the minimum concentrations of volatile sulphur compounds that can be practically distinguished from the background noise with the PFPD. The Hubaux-Vos detection limits and the AIS values are several times higher than the MDL, and provide more conservative estimates of the lowest concentrations that can be reliably detected. Sulphur detectivities are well correlated with AIS values but only poorly correlated with MDL values. The AIS is recommended as a reliable and cost-effective measure of detection limit for volatile sulphur compounds by GC-PFPD, since the AIS is easier and faster to determine than the MDL and the Hubaux-Vos detection limit. In addition, this study confirmed that the PFPD response is nearly quadratic with respect to concentration for all volatile sulphur compounds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of trace volatile sulfur compounds in milk by solid-phase microextraction and gas chromatography-pulsed flame photometric detection.

Volatile sulfur compounds have been reported to be responsible for the sulfurous off-flavors generated during the thermal processing of milk; however, their analysis has been a challenge due to their high reactivity, high volatility, and low sensory threshold. In this study, reactive thiols were stabilized and the volatile sulfur compounds in milk were extracted by headspace solid-phase microex...

متن کامل

Method for analysis of heavy sulphur compounds using gas chromatography with flame photometric detection

A method for analysis of heavy sulphur compounds in wines, based on gas chromatography (GC) with flame photometric detection, is reported. Wine samples preparation includes a dichloromethane liquid–liquid extraction followed by concentration under a nitrogen atmosphere. The extracted fraction was also analysed by GC–mass spectrometry. The method enables high recovery of sulphur compounds in win...

متن کامل

Determination of the Total Sulphur Content in Gas Oils with a Flame Photometric Detector

During a study of catalytic hydrodesulphurization of gas oils’ a method was needed not only for the determination of the distribution of sulphur compounds, but also, more importantly, for the determination of total suIphur content. Methods have been published for the determination of the distribution of sulpbur compounds in gas oils using gas chromatography (GC) with a coulometric detector’>3. ...

متن کامل

The Determination of Pesticidal and Non-Pesticidal Organotin Compounds in Water Matrices by in situ Ethylation and Capillary Gas Chromatography -[Pulsed] Flame Photometric Detection

The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detection, is described. The speciation analysis of nine organotin compounds includes low molecular weight low boiling (non...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1136 1  شماره 

صفحات  -

تاریخ انتشار 2006