Eliminating the need for refractive index matching in optical CT scanners for radiotherapy dosimetry: I. Concept and simulations.

نویسندگان

  • Simon J Doran
  • Dylan N B Yatigammana
چکیده

Optical computed tomography has now become a well-established method for making empirical measurements of 3D dose distributions in radiotherapy treatment verification. The requirement for effective refractive index matching as part of the scanning process has long been an inconvenience for users, limiting the speed of sample throughput. We propose a new method for reconstructing data that takes explicit account of the refracted path of the light rays and demonstrate theoretically the conditions under which there are sufficient data to create a good reconstruction. Examples of the performance of the algorithm are given. For smoothly varying data, reconstructed images of very high quality are obtained, with RMS deviation of under 1% from the original, provided that the irradiated region lies entirely within a critical radius. For the dosimeter material PRESAGE, this critical value is approximately 0.65 of the sample radius. Regions outside this are not reconstructed successfully, but we argue that there are many cases where this disadvantage is outweighed by the benefits of the technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and developing an in-house CCD based optical CT scanner for gel dosimetry

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT.

The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990's. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and ra...

متن کامل

Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT

The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990’s. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2012