Comparison of two PCR-based human papillomavirus genotyping methods.

نویسندگان

  • Philip E Castle
  • Carolina Porras
  • Wim G Quint
  • Ana Cecilia Rodriguez
  • Mark Schiffman
  • Patti E Gravitt
  • Paula González
  • Hormuzd A Katki
  • Sandra Silva
  • Enrique Freer
  • Leen-Jan Van Doorn
  • Silvia Jiménez
  • Rolando Herrero
  • Allan Hildesheim
چکیده

We compared two consensus primer PCR human papillomavirus (HPV) genotyping methods for the detection of individual HPV genotypes and carcinogenic HPV genotypes as a group, using a stratified sample of enrollment cervical specimens from sexually active women participating in the NCI/Costa Rica HPV16/18 Vaccine Efficacy Trial. For the SPF(10) method, DNA was extracted from 0.1% of the cervical specimen by using a MagNA Pure LC instrument, a 65-bp region of the HPV L1 gene was targeted for PCR amplification by using SPF(10) primers, and 25 genotypes were detected by reverse-line blot hybridization of the amplicons. For the Linear Array (LA) method, DNA was extracted from 0.5% of the cervical specimen by using an MDx robot, a 450-bp region of the HPV L1 gene was targeted for PCR amplification by using PGMY09/11 L1 primers, and 37 genotypes were detected by reverse-line blot hybridization of the amplicons. Specimens (n = 1,427) for testing by the LA method were randomly selected from strata defined on the basis of enrollment test results from the SPF(10) method, cytology, and Hybrid Capture 2. LA results were extrapolated to the trial cohort (n = 5,659). The LA and SPF(10) methods detected 21 genotypes in common; HPV16, -18, -31, -33, -35, -39, -45, -51, -52, -56, -58, -59, -66, -68, and -73 were considered the carcinogenic HPV genotypes. There was no difference in the overall results for grouped detection of carcinogenic HPV by the SPF(10) and LA methods (35.3% versus 35.9%, respectively; P = 0.5), with a 91.8% overall agreement and a kappa value of 0.82. In comparisons of individual HPV genotypes, the LA method detected significantly more HPV16, HPV18, HPV39, HPV58, HPV59, HPV66, and HPV68/73 and less HPV31 and HPV52 than the SPF(10) method; inclusion of genotype-specific testing for HPV16 and HPV18 for those specimens testing positive for HPV by the SPF(10) method but for which no individual HPV genotype was detected abrogated any differences between the LA and SPF(10) methods. The LA method detected more carcinogenic-HPV-genotype infections per specimen than the SPF(10) method (P < 0.001). In conclusion, the LA method and the SPF(10) method with HPV16 and HPV18 genotype-specific detection among ungenotyped HPV-positive specimens were comparable for detection of HPV16 and HPV18, the two HPV genotypes targeted by current prophylactic HPV vaccines. Both approaches are suitable for monitoring the impact of HPV16/18 vaccines in clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Digene HPV Genotyping LQ Test and the PANArray HPV Genotyping Chip for Detection of High-Risk or Probable High-Risk Human Papillomavirus Genotypes

BACKGROUND We evaluated the performance of two different array-based techniques, a bead-based multiplex genotyping method (LQ; digene HPV Genotyping LQ Test, QIAGEN, Germany) and a DNA chip-based method using peptide nucleic acid probes (PANArray; PANArray HPV Genotyping Chip, Panagene, Korea), for detection of human papillomavirus (HPV) and genotyping of high-risk (HR) or probable high-risk (P...

متن کامل

Comparison of real-time multiplex human papillomavirus (HPV) PCR assays with the linear array HPV genotyping PCR assay and influence of DNA extraction method on HPV detection.

Real-time human papillomavirus (HPV) type-specific multiplex PCR assays were developed to detect HPV DNA in specimens collected for the efficacy determination of the quadrivalent HPV (type 6, 11, 16, and 18) L1 virus-like particle (VLP) vaccine (Gardasil). We evaluated the concordance between type-specific multiplex HPV PCR and the widely used, commercially available Roche Linear Array genotypi...

متن کامل

Comparison of Four Human Papillomavirus Genotyping Methods: Next-generation Sequencing, INNO-LiPA, Electrochemical DNA Chip, and Nested-PCR

BACKGROUND Human papillomavirus (HPV) infection causes cervical cancer, thus necessitating early detection by screening. Rapid and accurate HPV genotyping is crucial both for the assessment of patients with HPV infection and for surveillance studies. METHODS Fifty-eight cervicovaginal samples were tested for HPV genotypes using four methods in parallel: nested-PCR followed by conventional seq...

متن کامل

Prevalence of Human Papillomavirus In Women With Abnormal Pap Smear In Boyer Ahmad City

  Abstract Background & aim: Human papillomavirus (HPV) is the most common sexually transmitted disease that is major risk factor for the development of precancerous and cancerous cervical lesions. This study was planned to evaluate the prevalence of HPV and its genotypes in women with abnormal Pap smear who referred to shahid Mofateh clininc. Methods: A total of 67 cervical cytology sample inc...

متن کامل

Comparison of the Seeplex HPV4A ACE and the Cervista HPV assays for the detection of HPV in hybrid capture 2 positive media

OBJECTIVE To validate the efficacy of Seeplex HPV4A ACE for the detection of high-risk (HR) human papillomavirus (HPV) and HPV 16 and/or HPV 18 genotypes as compared to the PCR method and the Cervista HPV assays in cervical swab samples. METHODS Besides liquid-based cytology, additional 97 cervical swab samples were collected for HPV genotyping by HPV4A ACE, Cervista HPV assays, and PCR metho...

متن کامل

Comparison of real-time multiplex human papillomavirus (HPV) PCR assays with INNO-LiPA HPV genotyping extra assay.

Real-time type-specific multiplex human papillomavirus (HPV) PCR assays were developed to detect HPV DNA in samples collected for the efficacy determination of the quadrivalent HPV (type 6, 11, 16, and 18) L1 virus-like particle (VLP) vaccine (Gardasil). Additional multiplex (L1, E6, and E7 open reading frame [ORF]) or duplex (E6 and E7 ORF) HPV PCR assays were developed to detect high-risk HPV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 46 10  شماره 

صفحات  -

تاریخ انتشار 2008