Evaluation of oesophageal reflectance pulse oximetry in major burns patients.
نویسندگان
چکیده
Pulse oximetry is being used in everyday clinical practice in anaesthesia utilising a peripheral probe. However, it may be unreliable in certain clinical situations such as hypothermia, hypovolemia, vasoconstriction and decreased cardiac output. Similar situations occur in burns patients and, more importantly, burns to extremities which limit the sites available for measurement of peripheral oxygen saturation (SpO(2)). To overcome these limitations, the oesophagus has been investigated as an alternative measurement site, as perfusion may be preferentially preserved centrally. A miniaturised reflectance oesophageal saturation (SpO(2)) probe has been constructed utilising infrared and red photodiodes and a photodetector. Our study was aimed at evaluating the reliability of oesophageal pulse oximetry in major burns patients. Seven adult patients (five males, two females) were studied. They were sedated and ventilated as part of their routine care. Measurable photoplethysmographic (PPG) traces and SpO(2) values were obtained in the oesophagus of all patients at a mean depth of 15.6+/-1.8 cm (measured from the lips). It was found that the oesophageal pulse oximeter results were in good agreement with oxygen saturation measurements obtained by a CO-oximeter. The mean (+/-S.D.) of the differences between the oesophageal oxygen saturation results and those from CO-oximetry was 0.50+/-0.69%. A Bland and Altman analysis showed that the bias and the limits of agreement between the oesophageal and commercial toe pulse oximeters were 0.4% and -3.6% to 4.6%, respectively. This study suggests that the oesophagus can be used as an alternative site for monitoring arterial blood oxygen saturation by pulse oximetry in burned patients.
منابع مشابه
Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery.
Pulse oximetry probes placed peripherally may fail to give accurate values of blood oxygen saturation when the peripheral circulation is poor. Because central blood flow may be preferentially preserved, we investigated the oesophagus as an alternative monitoring site. A reflectance blood oxygen saturation probe was developed and evaluated in 49 patients undergoing cardiothoracic surgery. The oe...
متن کاملInvestigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.
Pulse oximeter probes attached to the finger may fail to estimate blood oxygen saturation (SpO2) in patients with compromised peripheral perfusion (e.g. hypothermic cardiopulmonary bypass surgery). The measurement of SpO2 from a central organ such as the oesophagus is suggested as an alternative to overcome this problem. A reflectance oesophageal pulse oximeter probe and a processing system imp...
متن کاملCan we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?
Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملEvaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns
Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Burns : journal of the International Society for Burn Injuries
دوره 31 3 شماره
صفحات -
تاریخ انتشار 2005