Masked high-frequency bone-conduction audiometry: test reliability.
نویسندگان
چکیده
The present study examines the reliability of masked high-frequency bone-conduction threshold measurements in 95 normal-hearing subjects. High-frequency pure-tone air-and bone-conduction thresholds were measured with a dedicated laboratory high-frequency auditory evaluation system using matched, modified Koss Pro/4X Plus earphones, and the Pracitronic KH 70/5 bone vibrator. A 400-Hz wide band masking noise centered at the frequency of the test tone was used to mask the nontest ear. Monaural masked bone-conduction threshold measurements were obtained at the ipsilateral mastoid of the ear with better high-frequency hearing. Two measurements were performed in each session, and each subject participated in two sessions. In several comparisons for test-retest consistency, high-frequency bone-conduction threshold measurements were as repeatable as air-conduction thresholds of identical frequency, or bone-conduction thresholds for frequencies of 4 kHz and less. High-frequency bone-conduction threshold measurement appears to be a sufficiently reliable tool for diagnosis of auditory disorders.
منابع مشابه
Improving the Accuracy of Baha® Fittings through Measures of Direct Bone Conduction
OBJECTIVES Variability in Baha® sound processor fittings may arise from the nature of the implant-to-bone transmission as well as transcranial attenuation for patients with single-sided sensorineural deafness (SSD). One method of improving the predictability of Baha fittings is to measure the individual patient's actual bone conduction thresholds, thereby removing the influences of skin thickne...
متن کاملClinical validation of the AMTAS automated audiometer.
OBJECTIVE To validate the air- and bone-conduction AMTAS automated audiometry system. DESIGN Prospective study. Test-retest reliability was determined by assessing adults with AMTAS air- and bone-conduction audiometry. Accuracy was determined by comparing AMTAS and manual audiometry conducted on adults. AMTAS testing was conducted in a quiet room and manual audiometry in a sound booth. STUD...
متن کاملValidity of diagnostic computer-based air and forehead bone conduction audiometry.
Computer-based audiometry allows for novel applications, including remote testing and automation, that may improve the accessibility and efficiency of hearing assessment in various clinical and occupational health settings. This study describes the validity of computer-based, diagnostic air and forehead bone conduction audiometry when compared wtih conventional industry standard audiometry in a...
متن کاملValidity of Automated Threshold Audiometry: A Systematic Review and Meta-Analysis.
OBJECTIVES:: A systematic literature review and meta-analysis on the validity (test-retest reliability and accuracy) of automated threshold audiometry compared with the gold standard of manual threshold audiometry was conducted. DESIGN:: A systematic literature review was completed in peer-reviewed databases on automated compared with manual threshold audiometry. Subsequently a meta-analysis wa...
متن کاملIdentification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.
OBJECTIVES The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 2 2 شماره
صفحات -
تاریخ انتشار 1991