Comparison between BNP values measured in capillary blood samples with a POCT method and those measured in plasma venous samples with an automated platform.
نویسندگان
چکیده
*Corresponding author: Prof. Aldo Clerico, MD, Department of Laboratory Medicine, Fondazione CNR-Regione Toscana G. Monasterio, Scuola Superiore Sant ’ Anna, Via Moruzzi 1, 56126 Pisa, Italy, Phone: + 39 0585 493569, Fax: + 39 0585 493601, E-mail: [email protected] ; and Scuola Superiore Sant ’ Anna, Pisa, Italy Concetta Prontera, Michele Emdin and Claudio Passino: Fondazione CNR-Regione Toscana G. Monasterio, Pisa, Italy Silvia Masotti and Maria Franzini: Scuola Superiore Sant ’ Anna, Pisa, Italy Gian Carlo Zucchelli: QualiMedLab Spin-Off dell ’ Istituto di Fisiologia Clinica del CNR, Pisa, Italy Letter to the Editor
منابع مشابه
بررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد
Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...
متن کاملEvaluation of Hemoglobin Concentration of Cord, Capillary and Venous sampling in Neonates
Abstract Background Anemia is one of the most common abnormalities in pediatric medicine. Considerable differences are seen in the peripheral blood indices of infants in developing countries. The aim of this study was to determine and compared blood hemoglobin concentration in three sites of sampling in neonate. Materials and Methods 1600 term and preterm new infant in three sites of sampli...
متن کاملAccuracy and precision of analyses for total cholesterol as measured with the Reflotron cholesterol method.
We compared plasma cholesterol measurements made with the Boehringer Mannheim Reflotron reflectance photometric analyzer in 1298 capillary blood samples with measurements made in venous blood samples collected at the same time and analyzed in four standardized Lipid Research Clinics laboratories. The Reflotron measurements averaged 0.8% to 7.8% lower than the laboratory values. Correlations (r)...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملComparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol.
BACKGROUND Point of care (POC) glucose meters are routinely used to monitor glucose levels for patients on tight glycemic control therapy. We determined if glucose values were different for a POC glucose meter as compared to the main clinical laboratory for medical intensive care unit patients on a tight glycemic protocol and whether the site of blood sampling had a significant impact on glucos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 53 5 شماره
صفحات -
تاریخ انتشار 2015