Derivation of V function for LR 115 SSNTD from its sensitivity to 220Rn in a diffusion chamber.

نویسندگان

  • S Y Y Leung
  • D Nikezic
  • J K C Leung
  • K N Yu
چکیده

The sensitivity of the LR 115 detector inside a diffusion chamber to (220)Rn gas concentration is dependent on the removed active layer thickness during chemical etching. This dependence is related to the V function for the LR 115 detector (where V is the ratio between the track etch velocity V(t) and the bulk etch velocity V(b)) and the geometry of the diffusion chamber. The present paper presents the experimentally determined relationship between the sensitivity of the LR 115 detector inside a Karlsruhe diffusion chamber (determined from the number of etched tracks completely penetrating the active cellulose nitrate layer) and the removed active layer thickness. These data were used to derive the V function for the LR 115 detector, which took the functional form of the Durrani-Green's function, i.e., V=1+((a1e-)(a2R+a3e(-a)4R))(1(-e)(-a5R)), with the best-fitted constants as a(1)=14.50, a(2)=0.50, a(3)=3.9 and a(4)=0.066.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of LR 115 SSNTD in a diffusion chamber

Solid-state nuclear track detectors (SSNTDs), such as LR 115, have been commonly used in diffusion chambers for long-term measurements of radon gas concentrations. For the LR 115 SSNTD, it has been found that the active layer removed during chemical etching is significantly affected by the presence and amount of stirring, and thus cannot be controlled easily. However, the sensitivity of the LR ...

متن کامل

Derivation of V function for LR 115 SSNTD from its partial sensitivity to 222Rn and its short-lived progeny.

Solid-state nuclear track detectors (SSNTDs) have been widely applied for measurements of environmental concentrations of 222Rn and its progeny. The V function for an SSNTD is important for understanding the track development in the SSNTD as well as for real life applications. The partial sensitivity rhoi of the LR 115 detector applied in the bare mode to 222Rn and its short-lived progeny is re...

متن کامل

A study of the polyethylene membrane used in diffusion chambers for radon gas concentration measurements

Solid-state nuclear track detectors (SSNTDs) in diffusion chambers have been routinely used for long-term measurements of radon gas concentrations. In usual practice, a filter is added across the top of the diffusion chamber to stop the progeny from entering. Thoron can also be deterred from entering the diffusion chamber by using a polyethylene (PE) membrane. However, the thickness of the PE m...

متن کامل

Sensitivity of LR115 detector in diffusion chamber to 222Rn in the presence of 220Rn.

Determination has been made of the sensitivity of LR115 type 2-track detectors (in units of m) to 222Rn, measured in the presence of 220Rn. Measurements have been made by means of a widely used diffusion chamber while Monte Carlo simulations have also been conducted. The experimentally derived sensitivities for 222Rn and 220Rn were found to be 0.470+/-0.022 and 0.486+/-0.042 m, respectively. Fo...

متن کامل

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 65 3  شماره 

صفحات  -

تاریخ انتشار 2007