Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a feasibility study.

نویسندگان

  • Luca Ottaviano
  • Gian-Battista Chierchia
  • Alda Bregasi
  • Nicola Bruno
  • Andrea Antonelli
  • A T A Alsheraei
  • A M Porrini
  • E Gronda
  • F Donatelli
  • Anthonie-Leendert Duijnhower
  • Pedro Brugada
  • Annibale S Montenero
چکیده

AIMS Cryoballoon ablation (CBA; Arctic Front, Medtronic) has proven very effective in achieving pulmonary vein isolation. Real-time three-dimensional transoesophageal echocardiography (RT 3D TEE) is a novel technology, which permits detailed visualization of cardiac structures in a 3D perspective. The aim of the present study was to assess the feasibility, advantages, and safety of RT 3D TEE in guiding CBA in a series of patients affected by paroxysmal atrial fibrillation. METHODS AND RESULTS Forty-five patients (34 males, mean age: 63 ± 12 years) underwent CBA guided by 3D TEE. A total of 190 veins could be documented by TEE. Real-time three-dimensional transoesophageal echocardiography successfully guided the operator to position the CB in the pulmonary vein (PV) ostium and obtain complete occlusion in all 190 (100%) veins. Transoesophageal echocardiography identified leakages in 25 (13%) veins led to successful elimination of PV-left atrium (LA) backflow by guiding correct balloon repositioning. In four (2%) veins, this imaging tool led to perform successful pull-down manoeuvres. After a mean 2.6 ± 1.4 applications, isolation could be documented in 190 (100%) PVs. Median procedural and fluoroscopy times were 145 and 24 min. During a median follow-up of 278 days, 37 (82%) patients did not experience atrial fibrillation recurrence following a 3-month blanking period. CONCLUSION Cryoballoon ablation is safe and feasible under RT 3D TEE guidance. This imaging tool permits perfect visualization of all PV ostia and neighbouring LA structures. Most importantly, it proved very efficient in guiding the operator to achieve complete occlusion and successful isolation in all veins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact Of Real-Time Three Dimensional Transoesophageal Echocardiography Before Transcatheter Radiofrequency Ablation Of Atrial Fibrillation In Patients With Prosthetic Mechanical Mitral Valve.

Atrial fibrillation is the most common arrhythmia following valvular heart surgery. Radiofrequence catheter ablation of atrial fibrillation in patients with prothetic mechanical mitral valve is feasible and relatively safe in experienced center. Implementation of real-time three dimensional transoesophageal echocardiography in atrial fibrillation can demonstrate on-line left atrial and left atr...

متن کامل

Cryoballoon ablation for paroxysmal atrial fibrillation in the presence of an Amplatzer Septal Occluder device

Cryoballoon ablation of the pulmonary veins (CAPV) has been demonstrated to be non-inferior to radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AFib). As CAPV requires a larger transseptal sheath than RF ablation, it can be challenging in the presence of an AmplatzerTM Septal Occluder (ASO) device. Real-time three-dimensional transesophageal echocardiography (RT3DTEE) provides e...

متن کامل

First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablation.

AIMS Transseptal (TS) puncture during atrial fibrillation (AF) ablation is a relatively safe procedure in experienced hands. However, major and minor complications cannot be completely ruled out. Real-time three-dimensional transeosophageal echocardiography (RT 3D TEE) is a novel imaging technology that permits direct visualization of the fossa ovalis in a 3D perspective, thereby sensibly lower...

متن کامل

Nonfluoroscopic Ablation of Atrial Fibrillation Using Cryoballoon.

BACKGROUND The conventional method of cryoballoon ablation of atrial fibrillation involves the use of fluoroscopy for visual guidance. The use of fluoroscopy is accompanied by significant radiation risks to the patient and the medical staff. Herein, we report our experience in performing successful nonfluoroscopic pulmonary vein isolation using cryoballoon ablation in 5 consecutive patients wit...

متن کامل

Electro-Anatomic (CARTO) Mapping for Measurement of Left Atrial Volume: Validation Against Real-Time 3D Echocardiography

Background: Left atrial size is a determinant of atrial fibrillation ablation efficacy and embolic risk. The recent advent of real-time full-volume 3DE allows now rapid measurement of chamber volume more accurately than with standard two-dimensional echocardiography as volume is reconstructed from endocardial contours of the entire chamber without making geometric assumptions. Electro-anatomic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 15 7  شماره 

صفحات  -

تاریخ انتشار 2013