Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjects.
نویسندگان
چکیده
To gain more insight into the relationship between foveal and peripheral refractive errors in humans, spheres, cylinders, and their axes were binocularly measured across the visual field in myopic, emmetropic, and hyperopic groups of young subjects. Both automated infrared photorefraction (the "PowerRefractor"; www. plusoptix.de) and a double-pass technique were used because the PowerRefractor provided extensive data from the central 44 deg of the visual field in a very convenient and fast way. Two-dimensional maps for the average cross cylinders and spherical equivalents, as well as for the axes of the power meridians of the cylinders, were created. A small amount of lower-field myopia was detected with a significant vertical gradient in spherical equivalents. In the central visual field there was little difference among the three refractive groups. The established double-pass technique provided complementary data also from the far periphery. At 45 deg eccentricity the double-pass technique revealed relatively more hyperopic spherical equivalents in myopic subjects than in emmetropic subjects [+/-2.73 +/- 2.85 D relative to the fovea, p < 0.01 (+/- standard deviation)] and more myopic spherical equivalents in hyperopic subjects (-3.84 +/- 2.86 D relative to the fovea, p < 0.01). Owing to the pronounced peripheral astigmatism, spherical equivalents (refractions with respect to the plane of the circle of least confusion) became myopic relative to the fovea in all three groups. The finding of general peripheral myopia was unexpected. Its possible roles in foveal refractive development are discussed.
منابع مشابه
Peripheral refraction and image blur in four meridians in emmetropes and myopes
Introduction The peripheral refractive error of the human eye has been hypothesized to be a major stimulus for the development of its central refractive error. Aim The purpose of this study was to investigate the changes in the peripheral refractive error across horizontal, vertical and two diagonal meridians in emmetropic and low, moderate and high myopic adults. Subjects and methods Thirt...
متن کاملPeripheral refraction in different ethnicities.
PURPOSE Peripheral refraction is commonly used to infer retinal shape. Because of the different prevalence of myopia in the white compared with East Asian populations, peripheral refraction along the horizontal meridian was compared in white and East Asian young adults with emmetropic, low myopic, and moderately myopic refractive errors. METHODS Thirty-five white and 37 East Asian subjects we...
متن کاملPseudoaccommodative cornea treatment using the NIDEK EC-5000 CXIII excimer laser in myopic and hyperopic presbyopes.
PURPOSE To investigate the refractive outcomes and spherical aberration of multifocal LASIK to create a distant-dominant center and near-dominant periphery in hyperopic, myopic, and emmetropic presbyopia. METHODS One hundred ninety-five eyes with myopic presbyopia and 119 eyes with hyperopic or emmetropic presbyopia that underwent LASIK or epithelial LASIK (epi-LASIK) were assessed out to 3 m...
متن کاملTotal ocular, anterior corneal and lenticular higher order aberrations in hyperopic, myopic and emmetropic eyes
Total ocular higher order aberrations and corneal topography of myopic, emmetropic and hyperopic eyes of 675 adolescents (16.9 ± 0.7 years) were measured after cycloplegia using COAS aberrometer and Medmont videokeratoscope. Corneal higher order aberrations were computed from the corneal topography maps and lenticular (internal) higher order aberrations derived by subtraction of corneal aberrat...
متن کاملارتباط بیماری پرفشاری خون با عیوب انکساری چشم در بیماران درمانگاه چشم بیمارستان ولیعصر(عج) بیرجند (سال 1383)
Background and Aim: Refractive errors are the most common reasons for patients' reference to ophthalmology clinics. Regarding that systemic hypertension has significant complications in the eyes this study was done to determine the relationship between refractive errors and systemic hypertension. Materials and Methods: This descriptive, analytical and cross-sectional study was done on pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 19 12 شماره
صفحات -
تاریخ انتشار 2002