Multislice computed tomography-based prediction of the implantation plane in transcatheter aortic valve implantation: determination of the line of perpendicularity and the implanter's views.

نویسندگان

  • Andreas Holzamer
  • Emanuel Sitka
  • Christian Hengstenberg
  • Christof Schmid
  • Kurt Debl
  • Lars Maier
  • Daniele Camboni
  • Oliver Husser
  • Michael Hilker
چکیده

OBJECTIVES We demonstrate a multislice computed tomography (MSCT)-based method to calculate the prediction of the so-called 'line of perpendicularity' (LOP) and the 'implanter's views' (IVs) for transcatheter aortic valve implantation (TAVI) procedures. The LOP represents all possible angiographic angulations that result in an orthogonal view to the aortic annulus plane. The IVs allow visual confirmation of correct implantation planes, and are crucial for the commissural aligned implantation of second-generation TAVI prostheses. METHODS The LOP and IVs of 335 concomitant patients were prospectively analysed using multiple plane reconstruction (MPR) of the patient's MSCT scans. Exclusion criteria were bicuspid valves (n = 18) and valve-in-valve TAVI (n = 15). In the MPRs, the aortic cusps' lowest points were marked. With the marker's three-dimensional coordinates, the graph of the LOP with the IVs was calculated and plotted using vector mathematics. In the last 244 cases, the IV with the right coronary cusp in front was chosen for the first aortic root angiogram of the TAVI procedure. The finally used angulation was confirmed by aortic angiogram prior to the valve implantation. Solid angle differences that show the combined left anterior oblique/right anterior oblique and cranio/caudal movement of the C-arm allow quantification of corrections as well as demonstrate interindividual variations. RESULTS There is a broad interindividual variation of the aortic valve's topology with solid angle variations of up to 74°. The shape of the LOPs is extremely varying, especially regarding the slope of the curve that indicates differences in valve orientations. Among the 244 patients for whom we used the prediction for the procedure, the first angiogram was considered perfect for implantation without further corrections in 97% (n = 237) of them. In case of the 7 patients with subsequent corrections, the mean solid angle between the prediction and the final angiogram prior to implantation was 6.2° (±5°); the largest correction was 14°. CONCLUSIONS Prediction of the implantation plane by analysing the patient's MSCT is highly reliable in achieving an adequate view of the aortic annulus in TAVI. The analysis of LOPs showed the large interindividual differences that permit using a standard implantation plane. Therefore, we strongly recommend determining the LOP and IVs during the patient's screening process in each single TAVI case.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation.

OBJECTIVES This study assessed whether multislice computed tomography (MSCT) could predict optimal angiographic projections for visualizing the plane of the native valve and facilitate accurate positioning during transcatheter aortic valve implantation (TAVI). BACKGROUND Accurate device positioning during TAVI depends on valve deployment in angiographic projections perpendicular to the native...

متن کامل

Is time of renal hypoperfusion an important variable in determining response to renal artery revascularization?

3. Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2011;4:1235–45. 4. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before tran...

متن کامل

Imaging to select and guide transcatheter aortic valve implantation.

Transcatheter aortic valve implantation (TAVI) is indicated for patients with severe aortic stenosis and high or prohibitive surgical risk. Patients' selection requires clinical and anatomical selection criteria, being the later determined by multimodality imaging evaluation. Echocardiography, multislice computed tomography (MSCT), angiography, and cardiovascular magnetic resonance (CMR) are th...

متن کامل

SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relativ...

متن کامل

Transcatheter aortic valve implantation operators - get involved in imaging!

Pre-procedural planning is the key element of transcatheter aortic valve implantation (TAVI). Multislice computed tomography of the chest, abdomen and pelvis with the ability to perform a 3-dimensional reconstruction has become the cornerstone of pre-procedural planning. We would like to encourage TAVI operators (interventional cardiologist and surgeons) to get involved in imaging. All TAVI ope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 48 6  شماره 

صفحات  -

تاریخ انتشار 2015