4D flow MRI of the aorta becomes practical: performance and observer variability for a new semi-automated workflow for 3D visualization and quantification of aortic hemodynamics
نویسندگان
چکیده
Background To systematically investigate the performance and interobserver variability of a new standardized workflow for the analysis of aortic hemodynamics based on 4D-flow MRI in a study with 30 subjects. The semi-automated workflow was developed to ensure faster and standardized data analysis including systematic placement of analysis planes, 3D-flow visualization, and quantification of standard clinical flow parameters.
منابع مشابه
Comprehensive evaluation of aortic disease by in-vivo 4D flow MRI and 3D printing of patient-specific models: a feasibility study
Background Aortic diseases are often associated with changes in vessel geometry and blood flow. Currently available tools provide limited regional information that do not fully capture these complex alterations. Studies have shown that 4D flow MRI can be used for detailed in-vivo assessment of vascular hemodynamics with 3D visualization and quantification of aortic flow. Advances in rapid proto...
متن کاملReproducibility and inter-observer variability of velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
Background 4D flow MRI is a powerful tool to measure timeresolved three-directional blood flow in the pathological and healthy aorta. The 3D aortic velocity measured with 4D flow MRI allows for derivation of 3D wall shear stress (WSS), which is believed to be related to vessel wall remodeling and possibly an important biomarker for aortopathy. However, it is still unclear how variability of the...
متن کاملGlobal Pulse Wave Velocity in 87 Patients with Acute Ischemic Stroke and Aortic Atherosclerosis
Introduction: Increased pulse wave velocity (PWV) as a measure of aortic stiffness is an important marker for changes in aortic compliance and is an independent predictor of cardiovascular mortality and stroke. Reliable measurement of PWV is of particular interest for monitoring the progression or regression of vessel compliance during therapy [1-3]. Phase contrast (PC) MRI provides a noninvasi...
متن کاملCharacterisation of spatiotemporal aortic flow and aortic wall biomechanics in coarctation
The thoracic aorta performs sophisticated functions which depends largely on its almost unique structure. Coarctation of the aorta is a relatively common congenital anomaly, which causes a heavy burden of morbidity and mortality worldwide. As emphasized by Suradi and Hijazy in this issue of the journal, the long-term results can be very variable due to many factors. There is now a growing reali...
متن کاملComparison of 4D flow and 2D PC MRI blood flow quantification in children and young adults with congenital heart disease
Background Echocardiography (echo) is the primary imaging modality for assessment of aortic and pulmonary blood flow velocities. 2D phase contrast (PC) MRI provides better access to all segments of the aortic and pulmonary system and is considered the standard for evaluating blood flow. Both techniques are limited by velocity analysis in 2D planes and by single-direction velocity measurement wh...