Visual metaphors on anaesthesia monitors do not improve anaesthetists' performance in the operating theatre.
نویسندگان
چکیده
BACKGROUND Previous research using a metaphorical anaesthesia monitor, where dimensions of rectangles proportionally represent 30 patient variable values, showed improved performance in diagnosing adverse events compared with the standard monitor. Steady-state values were represented by a frame around each rectangle. We developed a similar metaphorical anaesthesia interface, but instead of presenting four relatively simple complications, we presented 10 complications of various levels of difficulty. Our simplified monitor presented variables that anaesthetists and trainees suggested as being essential for diagnosis. METHODS Thirty-two anaesthetists and anaesthesia trainees participated in the monitoring task. Three types of monitors were presented: standard monitor, metaphorical monitor, and metaphorical monitor with trend arrows emphasizing the direction of change. The subjects were presented with screenshots of the three monitor types displaying anaesthesia-related complications. They were asked to indicate treatment method and diagnosis for the displayed complication. RESULTS No significant differences were found in time to diagnosis and accuracy between the metaphorical and standard monitor. There were also no differences between trend and no-trend monitors. Forty per cent of the complications were identified incorrectly. CONCLUSIONS Visual metaphors on anaesthesia monitors do not improve anaesthetists' performance in the operating theatre. Since all complications in this study were identifiable based on monitor values alone, it seems feasible to develop a decision support system (DSS) based on these values. We suggest that a DSS could support the anaesthetist by calling attention to diagnoses that may not be considered.
منابع مشابه
Mood and cognitive functions in anaesthetists working in actively scavenged operating theatres.
Twenty-two anaesthetists participated in a study to assess the influence of occupational exposure to anaesthetic agents on mood (arousal and stress) and cognitive functions. In a cross-over design, each anaesthetist worked one day in a reference facility (for example, intensive care) and another day in a scavenged operating theatre where time-weighted exposure averaged nitrous oxide 58 p.p.m. a...
متن کاملIn-theatre training of anaesthetists in a teaching hospital: has it changed over 10 years?
BACKGROUND We wished to ascertain in what way recent changes such as Modernising Medical Careers (MMC) and the implementation of the Working Time Directive (WTD) have affected clinical training and experience for anaesthetists in a teaching centre, in particular the provision of training in specialized fields of anaesthesia provided in the teaching hospital. METHODS Data were extracted from t...
متن کاملTailoring reveals information requirements: the case of anaesthesia alarms
We discuss the phenomenon of system tailoring in the context of data from an observational study of anaesthesia. We found that anaesthetists tailor their monitoring equipment so that the auditory alarms are more informative. However, the occurrence of tailoring by anaesthetists in the operating theatre was infrequent, even though the flexibility to tailor exists on many of the patient monitorin...
متن کاملEvaluation of high fidelity patient simulator in assessment of performance of anaesthetists.
BACKGROUND There is increasing emphasis on performance-based assessment of clinical competence. The High Fidelity Patient Simulator (HPS) may be useful for assessment of clinical practice in anaesthesia, but needs formal evaluation of validity, reliability, feasibility and effect on learning. We set out to assess the reliability of a global rating scale for scoring simulator performance in cris...
متن کاملOperating Theatre Patient Monitoring: The Effects of Self Paced Distracter Tasks and Experimental Control on Sonification Evaluations
Three experiments were conducted to explore the effectiveness of continuous auditory displays, or sonifications, to convey information about simulated patient physiological state in dual task trials. Participants’ patient monitoring performance under different dual task conditions was investigated to determine if anaesthetic training was required to successfully use the sonification. A patient ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 110 5 شماره
صفحات -
تاریخ انتشار 2013