Temporally and Spatially Constrained ICA of fMRI Data Analysis

نویسندگان

  • Zhi Wang
  • Maogeng Xia
  • Zhen Jin
  • Li Yao
  • Zhiying Long
چکیده

Constrained independent component analysis (CICA) is capable of eliminating the order ambiguity that is found in the standard ICA and extracting the desired independent components by incorporating prior information into the ICA contrast function. However, the current CICA method produces constraints that are based on only one type of prior information (temporal/spatial), which may increase the dependency of CICA on the accuracy of the prior information. To improve the robustness of CICA and to reduce the impact of the accuracy of prior information on CICA, we proposed a temporally and spatially constrained ICA (TSCICA) method that incorporated two types of prior information, both temporal and spatial, as constraints in the ICA. The proposed approach was tested using simulated fMRI data and was applied to a real fMRI experiment using 13 subjects who performed a movement task. Additionally, the performance of TSCICA was compared with the ICA method, the temporally CICA (TCICA) method and the spatially CICA (SCICA) method. The results from the simulation and from the real fMRI data demonstrated that TSCICA outperformed TCICA, SCICA and ICA in terms of robustness to noise. Moreover, the TSCICA method displayed better robustness to prior temporal/spatial information than the TCICA/SCICA method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial and temporal independent component analysis of functional MRI data containing a pair of task-related waveforms.

Independent component analysis (ICA) is a technique that attempts to separate data into maximally independent groups. Achieving maximal independence in space or time yields two varieties of ICA meaningful for functional MRI (fMRI) applications: spatial ICA (SICA) and temporal ICA (TICA). SICA has so far dominated the application of ICA to fMRI. The objective of these experiments was to study IC...

متن کامل

Running head: Spatial- and Temporal-ICA of fMRI Spatial and Temporal Independent Component Analysis of functional MRI Data Containing a Pair of Task-Related Waveforms

Independent Component Analysis (ICA) is a technique that attempts to separate data into maximally independent groups. Achieving maximal independence in space or time yields two varieties of ICA meaningful for functional MRI (fMRI) applications: spatial-ICA (SICA) and temporal-ICA (TICA). SICA has so far dominated the application of ICA to fMRI. The objective of these experiments was to study IC...

متن کامل

Improving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase

Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...

متن کامل

Feature selection using genetic algorithm for classification of schizophrenia using fMRI data

In this paper we propose a new method for classification of subjects into schizophrenia and control groups using functional magnetic resonance imaging (fMRI) data. In the preprocessing step, the number of fMRI time points is reduced using principal component analysis (PCA). Then, independent component analysis (ICA) is used for further data analysis. It estimates independent components (ICs) of...

متن کامل

Quantification of motion-related artifacts in simulated FMRI data using ICA

I. Drobnjak, C. F. Beckmann, M. Jenkinson Oxford Centre for FMRI of the Brain, University of Oxford, Oxford, United Kingdom, Computing Laboratory, University of Oxford, Oxford, United Kingdom Introduction: FMRI data contain many motion-related artefacts which can limit its usefulness. Many approaches exist to correct for rigid-body motion effects but they struggle to do so in cases when motion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014