Template-directed instrumentation in total knee arthroplasty: cost savings analysis.

نویسندگان

  • Andrew R Hsu
  • Christopher E Gross
  • Sanjeev Bhatia
  • Brett R Levine
چکیده

The use of digital radiography and templating software in total knee arthroplasty (TKA) continues to become more prevalent as the number of procedures performed increases every year. Template-directed instrumentation (TDI) is a novel approach to surgical planning that combines digital templating with limited intraoperative instruments. The purpose of this study was to evaluate the financial implications and radiographic outcomes of using TDI to direct instrumentation during primary TKA. Over a 1-year period, 82 consecutive TKAs using TDI were retrospectively reviewed. Patient demographics and preoperative templated sizes of predicted components were recorded, and OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida was used to determine the 2 most likely tibial and femoral component sizes for each case. This sizing information was used to direct component vendors to prepare 3 lightweight instrument trays based on these sizes. The sizes of implanted components and the number of total trays required were documented. A cost savings analysis was performed to compare TDI and non-TDI surgical expenses for TKA. In 80 (97%) of 82 cases, the prepared sizes determined by TDI using 3 instrument trays were sufficient. Preoperative templating correctly predicted the size of the tibial and femoral component sizes in 90% and 83% of cases, respectively. The average number of trays used with TDI was 3.0 (range, 3-5 trays) compared with 7.5 (range, 6-9 trays) used in 82 preceding non-TDI TKAs. Based on standard fees to sterilize and package implant trays (approximately $26 based on a survey of 10 orthopedic hospitals performing TKA), approximately $9612 was saved by using TDI over the 1-year study period. Overall, digital templating and TDI were a simple and cost-effective approach when performing primary TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Conservative Bone Cuts and Technical Hints Incruciate Retaining Total Knee Arthroplasty, a 20 Years Experience

Total knee arthroplasty (TKA) is one of the most successful procedures in modern orthopedic surgery, providing high patient satisfaction rate. As a result, the number of patients undergoing TKA is increasing in number every year and more patients would be inclined to have the operation in near future . The demand for TKA is expected to grow 673% between 2005 and 2030. Knee surgeons are using mo...

متن کامل

Staphylococcus aureus Colonization in Patients Undergoing Total Hip or Knee Arthroplasty and Costeffectiveness of Decolonization Programme

Background: Periprosthetic joint infection is a devastating complication of total joint arthroplasty. It seems that thepatient’s skin, nose, throat, and urine are important sites for microbial colonization. Colonization with staphylococcusaureus, especially methicillin resistant increases the risk of periprosthetic joint infection. The aim of this study was toassess the prevalence of staphyloco...

متن کامل

Cost-effectiveness analysis of custom total knee cutting blocks.

The purposes of this study were to examine the cost-effectiveness of this technology and to determine improvements in patient outcome needed to make custom total knee cutting blocks cost-effective. A Markov decision model was used to evaluate the cost-effectiveness of custom cutting blocks compared with traditional instrumentation in total knee arthroplasty. The analysis demonstrates routine us...

متن کامل

Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty.

The purpose of this systematic review and meta-analysis is to compare patient-specific instrumentation (PSI) versus standard instrumentation for total knee arthroplasty (TKA) with regard to coronal and sagittal alignment, operative time, intraoperative blood loss, and cost. A systematic query in search of relevant studies was performed, and the data published in these studies were extracted and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 2012