Detachment and dislocation of thermoreactive clips from sternum in late postoperative period due to misuse.

نویسندگان

  • Murat Tavlasoglu
  • Mustafa Kurkluoglu
  • Zekeriya Arslan
  • Ahmet Baris Durukan
چکیده

Median sternotomy is the most common method of access to the heart and great vessels in cardiac surgical procedures. However, particularly in obese and diabetic patients, complications such as dehiscence, osteomyelitis, mediastinitis and superficial wound infection or fistula formation may be encountered. To overcome these complications, some alternative surgical techniques and surgical equipment are designed for sternal closure. 'Nitinol thermoreactive clips' is one of them. In this study, we report a patient with detachment of thermoreactive clips from sternum in the late postoperative period due to wrong measurement of distance between intercostal spaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined application of Robicsek procedure and thermoreactive nitinol clips for treating a patient with sternal dehiscence

Postopereative sternal dehiscence is one of the most important complications of median sternotomy which may cause pulmonary dysfunction and mediastinitis. We are reporting a patient with sternal dehiscence after coronary artery bypass surgery that underwent application of thermoreactive nitinol clips in addition to Robicsek procedure. Using thermoreactive nitinol clips method together with Robi...

متن کامل

Sternal closure using semirigid fixation with thermoreactive clips.

Sternomy represents the standard approach to the heart and great vessels in most cardiothoracic procedures. Closure of this incision is simple; however, healing complications such as dehiscence, osteomyelitis, mediastinitis, and superficial wound infection or fistula may occur. We describe an alternative technique for sternal closure using semirigid fixation with thermoreactive clips.

متن کامل

The ossification of the vertebral column, thorax and sternum in the quail (Coturnix coturnix japonica)

The ossification centers onset of the quail vertebrae, ribs, and sternum in embryos and hatchling birds was studied. Specimens were cleared, stained with Alcian Blue and Alizarin Red S and examined using stereomicroscope. The chondral rudiments of the vertebrae were observed at the 6th day of incubation (E6). The osteogenesis of the vertebrae was accomplished with both perichondral a...

متن کامل

Traumatic fracture of nitinol thermoreactive sternal clips.

Median sternotomy can be associated with significant morbidity, including non-union, dehiscence and mediastinitis. The use of flexible thermoreactive sternal clips has been introduced recently as an alternative method of sternal closure and is advocated in patients at increased risk of sternal breakdown. It is associated with a decreased incidence of sternal complications as well as allowing fa...

متن کامل

Suturing Technique to Promote Graft Attachment in Challenging Cases of Descemet Stripping Endothelial Keratoplasty

Aims: To describe a technique that uses a transcorneal fixation suture for graft attachment in endothelial keratoplasty in high-risk for graft dislocation eyes. Materials and Methods: Case series included 12 eyes of 12 patients who underwent Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in the presence of high risk for graft dislocation factors. We describe a surgical technique ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2012