Development of a testing method for the determination of interfacial micromotions of short-stemmed hip endoprosthesis.
نویسندگان
چکیده
Short stemmed hip endoprostheses represent a relevant alternative to standard sized total hip stems. Especially in terms of bone stock preservation and minimal invasiveness the reduced length of such implants is beneficial. However, the smaller implant size is linked to a reduced surface geometry and thereby bone-implant-interface to provide implant stability. In order to evaluate the interfacial micromotions of a short stem implant experimentally a new measurement device was developed and validated with an optical system.
منابع مشابه
Primary stability of cementless threaded acetabular cups at first implantation and in the case of revision regarding micromotions as indicators.
The primary stability of cementless total hip endoprosthesis is of vital importance for proximate, long-term osteointegration. The extent of micromotions between implant and acetabulum is an indicator of primary stability. Based on this hypothesis, different cementless hip joint endoprosthesis were studied with regard to their micromotions. The primary stability of nine different cementless thr...
متن کاملA new technique to measure micromotion distribution around a cementless femoral stem.
The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the...
متن کاملDetermination of Interfacial Area in Gas-Liquid Two Phase by Light Transmission
The purpose of the present paper is to develop light beam method to measurement of interfacial area in a rectangular gas-liquid bubble column. Total interfacial area can be determined in bubble column filled by transparent liquid by light transmission method. According to pervious researches, the fraction of parallel light is function of interfacial area and optical path l...
متن کاملDEVELOPMENT OF A METHOD FOR THE DETERMINATION OF 4-HYDROXY-3-METHOXYMANDELIC ACID (VANILLYLMANDELIC ACID) IN URINE BY PAPER CHROMATOGRAPHY
We have developed a simple and precise paper chromatographic method for the determination of 4-hydroxy-3-methoxymandelic acid (VMA) in urine. Concentrations of VMA in patients with neuroblastoma were increased in comparison to controls. The linearity was excellent in the concentration range tested. The within-assay coefficient of variation for control and patient urine was less than 2.2%. ...
متن کاملComputer and experimental analyses of the stress state in the cement hip joint endoprosthesis body.
BACKGROUND/AIM One of the possible complications after implantation of a cement hip-joint endoprosthesis is frac- ture in the endoprosthesis body. Fractures arise from overload or material fatigue of which an implant is made. The purpose of this research was to define the intensity of maximum stress and the positions of a critical cross-section in the endoprosthesis body. METHODS Unilaterally...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedizinische Technik. Biomedical engineering
دوره 57 Suppl 1 شماره
صفحات -
تاریخ انتشار 2012