Tension-free Polypropylene Mesh-related Surgical Repair for Pelvic Organ Prolapse has a Good Anatomic Success Rate but a High Risk of Complications

نویسندگان

  • Lei Zhang
  • Lan Zhu
  • Juan Chen
  • Tao Xu
  • Jing-He Lang
چکیده

BACKGROUND Food and Drug Administration announcements have highlighted the standard rate of mesh-related complications. We aimed to report the short-term results and complications of tension-free polypropylene mesh (PROSIMA™) surgical repair of pelvic organ prolapse (POP) using the standard category (C), timing (T), and site (S) classification system. METHODS A prospective cohort study of 48 patients who underwent PROSIMA™ mesh kit-related surgical repairs were followed for two years at Peking Union Medical College Hospital. Recurrence was defined as symptomatic POP quantification (POP-Q) Stage II or higher (leading edge ≥ -1 cm). The Patient Global Impression of Change Questionnaire, the Chinese version of the Pelvic Floor Impact Questionnaire short-form-7 and POP/Urinary Incontinence Sexual Questionnaire short-form-12 were used to evaluate the self-perception and sexual function of each patient. Mesh-related complications conformed to the International Urogynecological Association/International Continence Society joint terminology. The paired-sample t-test, one-way analysis of variance, Fisher's exact test, Kaplan-Meier survival analysis and log-rank test were used to analyze data. RESULTS All patients were followed up for ≥12 months; 30 (62.5%) patients completed the 24 months study. We observed a 93.8% (45/48) positive anatomical outcome rate at 12 months and 90.0% (27/30) at 24 months. Recurrence most frequently involved the anterior compartment (P < 0.05). Pelvic symptoms improved significantly from baseline (P < 0.05), although the patients' impressions of change and sexual function were not satisfying. Vaginal complication was the main complication observed (35.4%, 17/48). The survival analysis did not identify any relationship between vaginal complication and anatomical recurrent prolapse (POP-Q ≥ Stage II) (P = 0.653). CONCLUSIONS Tension-free polypropylene mesh (PROSIMA™ )-related surgical repair of POP has better short-term anatomical outcomes at the apical and posterior compartments, but a low patient satisfaction rate. The mesh complications were not the definitive cause of recurrence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laparoscopic-assisted tension-free vaginal mesh: an innovative approach to placing synthetic mesh: transvaginally for surgical correction of pelvic organ prolapse.

Polypropylene mesh implants for the correction of pelvic organ prolapse (POP) are now available in Japan. We developed an innovative approach for correcting POP by placing polypropylene mesh transvaginally with laparoscopic assistance. From June 2007 through March 2010, sixteen consecutive patients with symptomatic stage 2 or 3 pelvic organ prolapse underwent the laparoscopic-assisted tension-f...

متن کامل

Transvaginal mesh procedures for prolapse, analyzing its outcomes rates and complications-literature review

Objective of the study: To know the efficacy of transvaginal mesh repair augmented by synthetic polypropylene mesh for pelvic organ prolapse with objective and subjective result of the procedure. Material and methods: Evidence was gathered mostly about transvaginal synthetic polypropylene mesh using the search terms Transvaginal mesh, urinary incontinence, Mesh -complication, anterior prolapse,...

متن کامل

Simultaneous treatment of anterior vaginal wall prolapse and stress urinary incontinence by using transobturator four arms polypropylene mesh

PURPOSE To evaluate the medium-term efficacy and safety of transobturator four-arm polypropylene mesh in the treatment of high-stage anterior vaginal wall prolapse and concomitant stress urinary incontinence (SUI). MATERIALS AND METHODS Between September 2010 and August 2013, a prospective single-center trial was performed to evaluate women with stage≥3 anterior vaginal wall prolapse with or ...

متن کامل

The authors reply: Simultaneous treatment of anterior vaginal wall prolapse and stress urinary incontinence by using transobturator four arms polypropylene mesh.

To the editor: We greatly appreciate the interest in our work as commented on in your journal. In our article published in the Korean Journal of Urology in 2015 [1], we concluded that the Nazca-Tc system is effective and safe in the treatment of advanced anterior vaginal wall prolapse with a low rate of complications after medium-term follow-up. One of our study limitations was sexual inactivit...

متن کامل

Genital prolapse repair with Avaulta Plus mesh: functional results and quality of life.

PURPOSE Evaluate anatomic and functional outcomes of genital prolapse repair by vaginal route using a mixed polypropylene and porcine skin mesh. PATIENTS AND METHODS Prospective pilot study from January 2009 to January 2011 in the gynecologic department of a tertiary university hospital. Twenty patients with stage II-III genital prolapse underwent anterior wall prolapse repair with anterior A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 128  شماره 

صفحات  -

تاریخ انتشار 2015