Abnormal blood pathways in left ventricular cavity in acute myocardial infarction. Experimental observations with special reference to regional wall motion abnormality and hemostasis.

نویسندگان

  • S Beppu
  • S Izumi
  • K Miyatake
  • S Nagata
  • Y D Park
  • H Sakakibara
  • Y Nimura
چکیده

To elucidate the mechanism of regional hemostasis in the left ventricular (LV) cavity during myocardial infarction, the blood pathway in LV cavity was examined with contrast echocardiography injected from the left atrium before and after coronary ligation in nine canines. Before coronary ligation, contrast echoes spread over LV cavity with one rush. After ligation, smokelike echoes indicating hemostasis were observed at the apical middle of the LV cavity in five dogs with apical akinesis and at the apical area in four dogs with apical dyskinesis. The contrast echoes did not reach the apex within one diastolic period but turned upward to the outflow tract in the middle of the cavity in all dogs. In the cardiac beats that followed, some contrast echoes spread slowly toward the apex, forming a thin layer along the posterior wall in cases with akinesis but not in cases with dyskinesis. The area separated from the blood pathway developed where the smokelike echoes had been developed. Tachycardia exaggerated the abnormality of blood pathway and widened the contrast echo-free area. The abnormal pathway of the blood in apical myocardial infarction develops hemostasis in the apex. This should be one of the mechanisms of thrombus formation in myocardial infarction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Myocardial Infarction Experimental Observations With Special Reference to Regional Wall Motion Abnormality and Hemostasis

To elucidate the mechanism of regional hemostasis in the left ventricular (LV) cavity during myocardial infarction, the blood pathway in LV cavity was examined with contrast echocardiography injected from the left atrium before and after coronary ligation in nine canines. Before coronary ligation, contrast echoes spread over LV cavity with one rush. After ligation, smokelike echoes indicating h...

متن کامل

Paclitaxel-coated stent: is there a light at the end of the tunnel?

1. Firstenberg MS, Vandervoort PM, Greenberg NL, et al. Noninvasive estimation of transmitral pressure drop across the normal mitral valve in humans: importance of convective and inertial forces during left ventricular filling. J Am Coll Cardiol 2000;36:1942–9. 2. Beppu S, Izumi S, Miyatake K, et al. Abnormal blood pathways in left ventricular cavity in acute myocardial infarction. Experimental...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

Echoventriculographic detection, localization, and quantification of left ventricular asynergy in acute myocardial infarction. A correlative echo- and electrocardiographic study.

"Echoventriculography", an echocardiographic method specially developed to scan the regional function of the left ventricle, is introduced for studying left ventricular wall motion alteration in patients with acute myocardial infarction. Purposeful probe directions, a 2:1 magnification, and careful adjustment of the gain and reject levels allowed a direct echocardiographic scanning of practical...

متن کامل

Advantages and applications of the centerline method for characterizing regional ventricular function.

We sought to identify theoretical advantages and applications of the centerline method for quantitative assessment of regional ventricular function. Motion was measured along 100 chords constructed perpendicular to a centerline drawn midway between the end-diastolic and end-systolic contours, and normalized for heart size. Abnormality was expressed in units of standard deviations from the mean ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 1988