Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system.
نویسندگان
چکیده
OBJECTIVE Attenuation artifacts adversely affect the diagnostic accuracy of myocardial perfusion imaging. We assessed the clinical usefulness of X-ray CT based attenuation correction (AC) in patients undergoing myocardial perfusion imaging by comparing their myocardial AC- and non-corrected (NC) SPECT images with the coronary angiography (CAG). METHODS We retrospectively reviewed the myocardial SPECT images of 30 patients (18 men, 12 women; mean age 68 years). Thirteen of 30 patients with coronary artery disease (CAD) and 17 without CAD were confirmed by CAG. They underwent sequential CT and myocardial SPECT imaging with thallium-201 (111 MBq) under an exercise or pharmacological stress protocol using our combined SPECT/ CT system. Two readers reviewed the myocardial SPECT images for the presence of CAD on a 4-point scale where 1 = normal, 2 = probably normal, 3 = probably abnormal, and 4 = abnormal. Two reading sessions were held. First, non-corrected (NC)-SPECT and second, AC-SPECT images using X-ray CT images were interpreted. Interobserver variability was assessed with kappa statistics. Diagnostic performance (accuracy) of coronary arterial stenosis was compared between AC- and NC-images. RESULTS Interobserver agreement for visual assessment was substantial or almost perfect. For AC-images, the observer consensus for analysis was 0.84 for the LAD-, 0.87 for the LCX-, and 0.71 for the RCA-territory. For NC-images, it was 0.91, 0.71, and 0.78. AC resulted in statistically significant improvements in overall diagnostic accuracy (sensitivity/ specificity/accuracy = 76%/93%/89%, 67%/86%/81%, respectively, for AC- and NC-images). CONCLUSIONS Because of an increase in the specificity, diagnostic accuracy was significantly increased on AC-images. These preliminary data suggest that X-ray CT based AC in myocardial SPECT imaging has the potential to develop into a reliable clinical technique.
منابع مشابه
Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of nuclear medicine
دوره 19 6 شماره
صفحات -
تاریخ انتشار 2005