Safety and efficacy of biolimus-eluting stent with biodegradable polymer: insights from EINSTEIN (Evaluation of Next-generation drug-eluting STEnt IN patients with coronary artery disease) Registry

نویسندگان

  • Cristiano Freitas de Souza
  • Anwar Mohamed El Mouallem
  • Fábio Sândoli de Brito
  • Alexandre Antônio Cunha Abizaid
  • Breno Oliveira Almeida
  • Amanda Gonçalves Almeida
  • Teresa Cristina Dias Cunha Nascimento
  • Marco Antonio Perin
  • Adriano Caixeta
چکیده

OBJECTIVE To evaluate the incidence of major adverse cardiac events (cardiac death, or acute myocardial infarct, or target vessel revascularization) at one year in "real world" patients. METHODS The EINSTEIN registry is an observational, prospective, single center study that consecutively included 103 patients (152 lesions) treated with the BiomatrixTM stent, a biolimus A9-eluting stent with biodegradable polymer. RESULTS The mean age was 65.0±12.4 years; male gender represented 83.5% of the patients; and 37.9% of them were diabetic. At one-year, major adverse cardiac events occurred in 11.7% of the patients, including 2.9% of cardiac death, 4.9% of with non ST- segment elevation acute myocardial infarction, and 3.9% of target vessel revascularization. Stent thrombosis occurred in only 1% (1 patient) at one-yearfollow-up. CONCLUSION The present Registry suggests that new generation biolimus A9 drug-eluting stents are safe and effective in a "real world", all-comers patients, showing low rates of major cardiac adverse events on long-term follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.

BACKGROUND Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS This randomised, ...

متن کامل

Clinical outcomes with Biolimus (A9)™ eluting stent, 'BioMatrix' in diabetic patients--interim results from multicenter post market surveillance registry in India.

OBJECTIVE The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. BACKGROUND Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non dia...

متن کامل

The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.

INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compar...

متن کامل

Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention

In percutaneous coronary interventions, drug-eluting stents (DESs) have reduced the risk of restenosis and repeat revascularization compared with bare-metal stents. The secondgeneration DESs with thinner stent struts have improved safety and efficacy compared with the first-generation DESs and has been associated with a reduced risk of late stent thrombosis. The persistence of polymer material ...

متن کامل

Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis

OBJECTIVES To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES). DESIGN Network meta-analysis of randomised controlled trials. DATA SOURCES AND STUDY SELECTION Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2013