Tissue surface as the reference arm in Fourier domain optical coherence tomography.
نویسندگان
چکیده
We present a simple method applicable to common-path Fourier domain optical coherence tomography (OCT) in which the tissue surface is used as the reference arm. We propose using aluminium hydroxide powder as a potential tissue surface diffuser to allow wider application of this method. This technique allows one to avoid placing a reference arm reflective element, such as glass plate, on tissue, and intrinsically avoids both coherent and complex conjugate mirror artifacts associated with glass plates. Aluminium hydroxide can be sprayed onto tissue using spray nozzles commonly found in endoscopes. The sensitivity of the tissue reference arm common-path OCT image is 94 dB for a 50-[micro sign]s charge-coupled device integration time, and 97.5 dB for a 200-[micro sign]s CCD integration time.
منابع مشابه
Dispersion Compensation in Spectral Domain Optical Coherence Tomography
Dispersion in spectral domain optical coherence tomography (SD OCT) system cause a degradation of point spread function (peak broadening) after FFT of the spectrum with the increase of the optical path distance between an object and reference arm. Different sources of dispersion and methods for the compensation are shown.
متن کاملاندازهگیری همزمان ضریب شکست و ضخامت فیزیکی دستگاههای چندلایهای با استفاده از نتایج مقطعنگاری همدوسی اپتیکی در فضای فوریه
In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...
متن کاملSynchronous self-elimination of autocorrelation interference in Fourier-domain optical coherence tomography.
We have developed a new algorithm and configuration for self-eliminating the autocorrelation of the object wave in Fourier-domain optical coherence tomography. A self-interferogram of the object wave is acquired synchronously with the standard interferogram of the recombined object and reference waves. The former is then subtracted from the latter after Fourier transformation. The algorithm is ...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملFeasibility Assessment of Optical Coherence Tomography-Guided Laser Labeling in Middle Cranial Fossa Approach
Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC)in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2012