Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses.
نویسندگان
چکیده
A systematic, comprehensive strategy that optimizes sample preparation and chromatography to minimize matrix effects in bioanalytical LC/MS/MS assays was developed. Comparisons were made among several sample preparation methods, including protein precipitation (PPT), liquid-liquid extraction (LLE), pure cation exchange solid-phase extraction (SPE), reversed-phase SPE and mixed-mode SPE. The influence of mobile phase pH and gradient duration on the selectivity and sensitivity for both matrix components and basic analytes was investigated. Matrix effects and overall sensitivity and resolution between UPLC technology and HPLC were compared. The amount of specific matrix components, or class of matrix components, was measured in the sample preparation extracts by LC/MS/MS with electrospray ionization (ESI) using both precursor ion scanning mode and multiple reaction monitoring (MRM). PPT is the least effective sample preparation technique, often resulting in significant matrix effects due to the presence of many residual matrix components. Reversed-phase and pure cation exchange SPE methods resulted in cleaner extracts and reduced matrix effects compared to PPT. The cleanest extracts, however, were produced with polymeric mixed-mode SPE (both reversed-phase and ion exchange retention mechanisms). These mixed-mode sorbents dramatically reduced the levels of residual matrix components from biological samples, leading to significant reduction in matrix effects. LLE also provided clean final extracts. However, analyte recovery, particularly for polar analytes, was very low. Mobile phase pH was manipulated to alter the retention of basic compounds relative to phospholipids, whose retention tends to be relatively independent of pH. In addition to the expected resolution, speed and sensitivity benefits of UPLC technology, a paired t-test demonstrated a statistically significant improvement with respect to matrix effects when this technology was chosen over traditional HPLC. The combination of polymeric mixed-mode SPE, the appropriate mobile phase pH and UPLC technology provides significant advantages for reducing matrix effects resulting from plasma matrix components and in improving the ruggedness and sensitivity of bioanalytical methods.
منابع مشابه
Comprehensive identification of sphingolipid species by in silico retention time and tandem mass spectral library
BACKGROUND Liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is used for comprehensive metabolome and lipidome analyses. Compound identification relies on similarity matching of the retention time (RT), precursor m/z, isotopic ratio, and MS/MS spectrum with reference compounds. For sphingolipids, however, little information on the RT and MS/MS re...
متن کاملCharacterization and classification of matrix effects in biological samples analyses.
An exhaustive classification of matrix effects occurring when a sample preparation is performed prior to liquid-chromatography coupled to mass spectrometry (LC-MS) analyses was proposed. A total of eight different situations were identified allowing the recognition of the matrix effect typology via the calculation of four recovery values. A set of 198 compounds was used to evaluate matrix effec...
متن کاملIdentification of miR-24 and miR-137 as novel candidate multiple sclerosis miRNA biomarkers using multi-staged data analysis protocol
Many studies have investigated misregulation of miRNAs relevant to multiple sclerosis (MS) pathogenesis. Abnormal miRNAs can be used both as candidate biomarker for MS diagnosis and understanding the disease miRNA-mRNA regulatory network. In this comprehensive study, misregulated miRNAs related to MS were collected from existing literature, databases and via in silico prediction. A multi-staged...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملUsing Visualized Matrix Effects to Develop and Improve LC-MS/MS Bioanalytical Methods, Taking TRAM-34 as an Example
Matrix effects (MEs) continue to be an obstacle in the development of the LC-MS/MS method, with phospholipids being the major cause of MEs. Changing the mobile phase has been a common strategy to reduce MEs; however, the underlying mechanism is unclear. "In-source multiple-reaction monitoring" (IS-MRM) for glycerophosphocholines (PCs) has been commonly applied in many bioanalytical methods. "Vi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
دوره 852 1-2 شماره
صفحات -
تاریخ انتشار 2007