Stability-indicating liquid chromatographic method for the determination of Letrozole in pharmaceutical formulations
نویسندگان
چکیده
A stability-indicating high-performance liquid chromatographic method was developed and validated for the determination of Letrozole in tablet dosage forms. Reversed-phase chromatography was performed on Shimadzu Model LC-Class-Vp with Lichrocart/Lichrosphere 100 C-18 (250 mm×4.6 mm, 5 μm particle size) column with methanol: tetra butyl ammonium hydrogen sulfate (80:20V/V) as mobile phase at a flow rate of 1 mL/min with UV detection at 240 nm. Linearity was observed in the concentration range of 0.5-150 μg/mL (R2=0.9998) with regression equation y=102582x+43185. The limit of quantitation (LOQ) and limit of detection (LOD) were found to be 0.043 and 0.012 μg/mL respectively. The forced degradation studies were performed by using HCl, NaOH, H2O2, thermal and UV radiation. Letrozole is more sensitive towards alkaline conditions and very much resistant towards acidic, oxidative and photolytic degradations. The method was validated as per ICH guidelines. The RSD for intra-day (0.78-0.97) and inter-day (0.86-0.96) precision were found to be lesser than 1%. The percentage recovery was in good agreement with the labeled amount in the pharmaceutical formulations and the method is simple, specific, precise and accurate for the determination of Letrozole in pharmaceutical formulations.
منابع مشابه
A Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کاملA Novel High Performance Liquid Chromatographic Method for Determination of Nystatin in Pharmaceutical Formulations by Box–Behnken Statistical Experiment Design
this study a novel High Performance Liquid Chromatography for the assay of nystatin in oral and vaginal tablets were optimized and validated using Box–Behnken experimental design. The method was performed in the isocratic mode on a RP-18 column (30 °C) using a mobile phase consisting of 0.05 M ammonium acetate buffer/ Methanol mixture (30:70) and a flow-rate of 1.0 ml/min. The method was valida...
متن کاملStability indicating liquid chromatographic method for the simultaneous determination of rosuvastatin and ezetimibe in pharmaceutical formulations.
PURPOSE A simple stability indicating reverse phase liquid chromatographic method was developed for the simultaneous determination of rosuvastatin and ezetimibe in pharmaceutical formulations. METHODS Best chromatographic response was achieved with C18 column (250 X 4.6 mm, 5µm) with photo diode array (PDA) detector. The mobile phase was composed of a mixture of sodium acetate buffer (pH 4.0)...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کامل