Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.
نویسندگان
چکیده
The performance of an amperometric biosensor, consisting of a subcutaneously implanted miniature (0.29 mm diameter, 5 x 10(-4) cm2 mass transporting area), 90 s 10-90% rise/decay time glucose electrode, and an on-the-skin electrocardiogram Ag/AgCl electrode was tested in an unconstrained, naturally diabetic, brittle, type I, insulin-dependent chimpanzee. The chimpanzee was trained to wear on her wrist a small electronic package and to present her heel for capillary blood samples. In five sets of measurements, averaging 5 h each, 82 capillary blood samples were assayed, their concentrations ranging from 35 to 400 mg/dl. The current readings were translated to blood glucose concentration by assaying, at t = 1 h, one blood sample for each implanted sensor. The rms error in the correlation between the sensor-measured glucose concentration and that in capillary blood was 17.2%, 4.9% above the intrinsic 12.3% rms error of the Accu-Chek II reference, through which the illness of the chimpanzee was routinely managed. Linear regression analysis of the data points taken at t>1 h yielded the relationship (Accu-Chek) = 0. 98 x (implanted sensor) + 4.2 mg/dl, r2 = 0.94. The capillary blood and the subcutaneous glucose concentrations were statistically indistinguishable when the rate of change was less than 1 mg/(dl. min). However, when the rate of decline exceeded 1.8 mg/(dl.min) after insulin injection, the subcutaneous glucose concentration was transiently higher.
منابع مشابه
Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)
OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...
متن کاملOsmium Bipyridyl Redox Polymers Used in Enzyme Electrodes
A review of the background of biosensors which utilise osmium complexes for monitoring the glucose levels in diabetic patients is presented. A n electrochemical system, based on an osmium redox polymer, is described; the system is aimed at being a reliable, compact and miniature in vivo sensor for implantation into diabetic patients for continuous monitoring of their blood glucose levels. The s...
متن کاملAmperometric glucose sensor for real time extracellular glucose monitoring in microfluidic device
We have combined a microfluidic network and developed a miniature glucose sensor to measure glucose consumption of single cardiomyocytes in a confined extracellular space. The thin film glucose sensor was integrated into a 360 picoliter extracellular space. We used Pt thin film electrodes (20x100 μm) as a counter electrode, and a needle type reference electrode (0.45 mm diam) placed in the cell...
متن کاملContinuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
A study was performed to examine the feasibility of achieving long periods of near-normoglycaemia in patients with diabetes mellitus by giving a continuous subcutaneous infusion of insulin solution from a miniature, battery-driven, syringe pump. Twelve insulin-dependent diabetics had their insulin pumped through a subcutaneously implanted, fine nylon cannula; the basal infusion rate was electro...
متن کاملThe Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes
The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the National Academy of Sciences of the United States of America
دوره 95 11 شماره
صفحات -
تاریخ انتشار 1998