Comparative study of preparation of hazardous drugs with different closed-system drug transfer devices by means of simulation with fluorescein.

نویسندگان

  • Eva González-Haba Peña
  • Silvia Manrique Rodríguez
  • Ana Mª Herranz Alonso
  • Patricia Pérez Castán
  • Mónica Moreno Gálvez
  • Irene Iglesias Peinado
  • María Sanjurjo Saez
چکیده

OBJECTIVES The level of environmental contamination generated during preparation and administration of hazardous drugs using different valve closed-systems and their combinations was compared. The actual impact on the overall time of preparation of cytostatics and the economic cost of the different modalities were also compared. METHODS Comparative study of the preparation of fluorescein mixtures with different modalities of valve closed-system combinations. Environmental contamination was detected in critical points of connection, and in splashes produced at any other points. The main variable was qualitative detection of contamination by splashes through ultraviolet light when modalities with or without a connector were compared. A final number of 160 mixtures were prepared to detect differences of at least 5%. RESULTS Splashes were produced in 7 preparations without a connector (p = 0.015). No significant differences (p = 0.445) were detected either in the use of a supporting vial spike vs an anchoring spike, or in the ChemoCLAVE® system vs valve systems with Fleboflex® solutions. Contamination at any critical point was produced in all preparations. The use of a supporting vial spike, syringe connector and bag solution with Luer connection was the most efficient modality. CONCLUSIONS A syringe connector is needed to guarantee a closed system. Anchoring spikes do not show higher advantages as compared with supporting vial spikes. Fleboflex® solutions with Luer bags are more efficient than ChemoCLAVE® and show similar safety. However, connections of these closed systems are not leak-tight, and it is therefore important to continue studies of contamination of the different closed system transfer devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining Sources of Workplace Contamination with Antineoplastic Drugs and Comparing Conventional IV Drug Preparation with a Closed System

Many procedures involved in the preparation and administration of hazardous drugs put health care workers at risk of exposure to these agents through leakage or accidental spills. The first objective of this study was to determine if the conventional needle/syringe technique has the potential to allow drugs to escape into the environment. The second objective was to evaluate if a closed system,...

متن کامل

A summary of the published clinical evidence of the effectiveness of the BD PhaSeal closed-system drug transfer device (CSTD)

Purpose. The primary objective of this study was to compare the levels of environmental contamination before and after the introduction of PhaSeal (closed-system drug transfer device) in two hospital pharmacies. Our secondary objective was to assess the impact of the device on the duration of drug preparation compared to procedures involving the use of needles and syringes. Methods. The study i...

متن کامل

Simulation and Experimental Verification of Closed Loop Operation of Buck / Boost DC-DC Converter with Soft Switching

A major problem in an isolated DC/DC converters operating at high switching frequencies is the attendant switching losses in the semiconductor devices. This can be reduced by introducing either zero-voltage switching (ZVS) or zero-current switching (ZCS) of the semiconductor switches. This paper deals with the simulation, design, fabrication and experimental evaluation of a novel soft-switching...

متن کامل

Medication errors in intravenous drug preparation and administration at intensive care unit

Background: Intravenous (IV) injection of drugs is one of the most common methods of drug prescription in hospitals, which is a complex, potentially hazardous and erroneous method; accordingly, it requires control methods to reduce the potential risks. This study focused on determining the frequency and types of different medication errors while preparing and administering mostly used IV drugs ...

متن کامل

Preparation of Pluronic/Bile salt/Phospholipid Mixed Micelles as Drug Solubility Enhancer and Study the Effect of the PPO Block Size on the Solubility of Pyrene

Pluronic/bile salt/phospholipid mixed micelles (Pluronic/BS/PS-MM) drug carrier system for solubilization hydrophobic drugs was developed. A typical hydrophobic compound, pyrene, was selected as a representative hydrophobic compound to model the hydrophobic drugs. Five Pluronics, F68, F88, F98, F108, and F127 with different PPO chain length were studied. CMC data and solubilization capacities w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Farmacia hospitalaria : organo oficial de expresion cientifica de la Sociedad Espanola de Farmacia Hospitalaria

دوره 40 n06  شماره 

صفحات  -

تاریخ انتشار 2016