This paper describes an electrochemical enzyme-linked immunosorbent assay (ELISA) on paper-based microfluidic devices. This paper-based immunoassay method has several advantages over conventional ELISA, such as short assay time, low cost, and high sensitivity. The limit of detection (LOD) of rabbit IgG used as a model system is ~ 3.9 fM; this value is lower than the LOD of paper-based colorimetric ELISA (~54 fM).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Folding Analytical Devices for Electrochemical ELISA in Hydrophobic R Paper

This work describes a device for electrochemical enzyme-linked immunosorbent assay (ELISA) designed for low-resource settings and diagnostics at the point of care. The device is fabricated entirely in hydrophobic paper, produced by silanization of paper with decyl trichlorosilane, and comprises two zones separated by a central crease: an embossed microwell, on the surface of which the antigen o...

متن کامل

Folding analytical devices for electrochemical ELISA in hydrophobic R(H) paper.

This work describes a device for electrochemical enzyme-linked immunosorbent assay (ELISA) designed for low-resource settings and diagnostics at the point of care. The device is fabricated entirely in hydrophobic paper, produced by silanization of paper with decyl trichlorosilane, and comprises two zones separated by a central crease: an embossed microwell, on the surface of which the antigen o...

متن کامل

Bifunctional tri(ethylene glycol) alkanethiol monolayer modified gold electrode for on-chip electrochemical immunoassay of pg level leptin.

An on-chip enzyme-linked immunosorbent assay combined with an electrochemical detection method (EC-ELISA) was employed to detect a leptin, one of the most important adipose derived hormones, using gold electrodes modified with a tri(ethylene glycol) terminated short alkanethiol (TEGCnSH, Cn = (CH(2))n, n = 2, 4, 6, and 8) monolayer. These TEGCnSH monolayers on gold electrodes can suppress non-s...

متن کامل

Electrochemical enzyme-linked immunosorbent assay (ELISA) for α-fetoprotein based on glucose detection with multienzyme-nanoparticle amplification.

Since glucose biosensors are one of the most popular and widely used point-of-care testing devices, a novel electrochemical enzyme-linked immunosorbent assay (ELISA) for protein biomarkers has been developed based on a glucose detection strategy. In this study, α-fetoprotein (AFP) was used as the target protein. An electrochemical ELISA system was constructed using anti-AFP antibodies immobiliz...

متن کامل

A nanocoaxial-based electrochemical sensor for the detection of cholera toxin.

Sensitive, real-time detection of biomarkers is of critical importance for rapid and accurate diagnosis of disease for point of care (POC) technologies. Current methods do not allow for POC applications due to several limitations, including sophisticated instrumentation, high reagent consumption, limited multiplexing capability, and cost. Here, we report a nanocoaxial-based electrochemical sens...