Explantation of aortic infrarenal stent graft

نویسندگان

  • J Krysa
  • PR Taylor
چکیده

end of the stent graft is extracted from the aorta. If another graft is used, proximal anastomosis is carried out with the balloon inflated. To complete the anastomosis a second Foley catheter is passed through a limb of the new graft (Fig 2). While the original catheter is deflated and removed, the second balloon is inflated in the suprarenal aorta (Fig 3) and the anastomosis completed. ACKNOWLEDGEMENT We would like to thank James Clark for his help with the drawings. TECHNIQUE Pass a drill guide through the jig used for inserting proximal screws. Leave the drill guide in position against the limb. This can now be used to align the C-arm. Position the C-arm distally and adjust its position until it is parallel to the drill guide in its orbital and swivel axis. This will give near perfect alignment to the distal locking holes. Finer adjustments may be needed under image intensifier guidance to gain the final position. Once satisfactory alignment is achieved, insert the distal screws as usual.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

In Situ Aortic Reconstruction with Femoral Vein after Post-EVAR Infection

A 78-year-old male presented with early gastric cancer and a 5.5 cm-sized infrarenal abdominal aortic aneurysm, detected during regular screening. Endovascular aneurysm repair (EVAR) was performed first, followed by laparoscopic distal gastrectomy. After gastrectomy, the patient underwent computed tomography (CT) scan due to persistent fever, which showed increased perigraft fluid collection ar...

متن کامل

Posttraumatic infrarenal abdominal aortic pseudoaneurysm treated with bifurcated endovascular graft stent

Posttraumatic infrarenal aortic pseudoaneurysms are rare and potentially lethal lesions. We report the case of a 32-year-old man presenting with infrarenal aortic pseudoaneurysm eight months after being stabbed in the back and right flank. His pseudoaneurysm was close to the iliac bifurcation, so we decided to deploy a bifurcated endovascular graft stent, the TriVascular Ovation endovascular st...

متن کامل

Changes in suprarenal and infrarenal aortic angles after endovascular aneurysm repair

PURPOSE We investigated whether suprarenal and infrarenal aortic angles change after the endovascular aneurysm repair (EVAR) procedure and during follow-up, and investigated the correlation between infrarenal aortic angle after EVAR and type Ia endoleaks. METHODS Data collected on 70 EVAR procedures for a fusiform infrarenal aortic aneurysm performed between May 2006 and December 2012 were su...

متن کامل

Banding in aortic stent-graft fixation in EVAR.

The authors describe the method of surgical aortic banding for better stent-graft fixation in cases of problematic aortic neck in the endovascular infrarenal aneurysms repair.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2012