A spherical dose model for radiosurgery plan optimization.
نویسندگان
چکیده
Conventional 3D dose calculations for stereotactic radiosurgery involve integration of individual static beams comprising a set of arcs. For iterative optimization of multiple isocentre treatment, which requires repetitive dose calculations at a large number of sample points, the conventional method is too slow. To overcome this problem spherically symmetric dose distributions are assumed. The authors describe a spherical dose model derived from a parametrized convolution of the collimator width and a dose spread kernel. The method is fast and easy to implement requiring just a single empirically derived value. Furthermore, the model is differentiable with respect to the parameters to be optimized. This property is useful when the optimization strategies rely on gradient information.
منابع مشابه
A phantom study to determine the optimum size of a single collimator for shortening the treatment time in CyberKnife stereotactic radiosurgery of spherical targets
Prolonged treatment execution time is a concern in CyberKnife robotic radiosurgery. Beam reduction and node reduction technique, and monitor unit optimization methods are adopted to reduce the treatment time. Usage of single collimator in the CyberKnife treatment plan can potentially reduce collimator exchange time. An optimal single collimator, which yields an acceptable dose distribution alon...
متن کاملInverse treatment planning for spinal robotic radiosurgery: an international multi‐institutional benchmark trial
Stereotactic radiosurgery (SRS) is the accurate, conformal delivery of high-dose radiation to well-defined targets while minimizing normal structure doses via steep dose gradients. While inverse treatment planning (ITP) with computerized optimization algorithms are routine, many aspects of the planning process remain user-dependent. We performed an international, multi-institutional benchmark t...
متن کاملRadiotoxicity in robotic radiosurgery: proposing a new quality index for optimizing the treatment planning of brain metastases
BACKGROUND As irradiated brain volume at 12 Gy (V12) is a predictor for radionecrosis, the purpose of the study was to develop a model for Cyberknife (CK) plans that is able to predict the lowest achievable V12 at a given tumor size and prescription dose (PD), and to suggest a new quality index regarding V12 for optimizing the treatment planning of brain metastases. METHOD In our model V12 wa...
متن کاملThe Relationship Between the Number of Shots and the Quality of Gamma Knife Radiosurgeries
Radiosurgery is a non-invasive alternative to brain surgery that uses a single focused application of high radiation to destroy intracerebral target tissues. A Gamma Knife delivers such treatments by using 201 cylindrically collimated cobalt-60 sources that are arranged in a hemispherical pattern and aimed to a common focal point. The accumulation of radiation at the focal point, called a “shot...
متن کاملOptimization of multiple-isocenter treatment planning for linac-based stereotactic radiosurgery.
OBJECTIVE Computer-assisted treatment planning for linac-based radiosurgery is still an open research problem, especially for multiple-isocenter procedures, primarily due to its high complexity and computational requirements. This paper focuses on the optimization of multiple-isocenter treatment planning for linac systems, and addresses several important issues associated with multiple isocente...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 43 10 شماره
صفحات -
تاریخ انتشار 1998