Low temperature PAN cross-sections
نویسندگان
چکیده
Low temperature mid-infrared cross-sections for peroxyacetyl nitrate (PAN) vapour G. Allen, J. J. Remedios, and K. M. Smith EOS, Space Research Centre, Department of Physics and Astronomy, University of Leicester, Leicester, LE1 7RH, UK Space Science and Technology Department, Rutherford Appleton Laboratory, Didcot, Oxon, OX11 0QX, UK Received: 7 June 2005 – Accepted: 12 July 2005 – Published: 8 August 2005 Correspondence to: G. Allen ([email protected]) © 2005 Author(s). This work is licensed under a Creative Commons License.
منابع مشابه
Low temperature mid-infrared cross-sections for peroxyacetyl nitrate (PAN) vapour
Laboratory absorption spectra of peroxyacetyl nitrate (PAN, CH3C(O)OONO2) vapour have been measured in the mid-infrared range 550 cm−1 to 1400 cm−1 (18.2 to 7.14μm) at both 250 K and 273 K, using a Fourier transform infrared spectrometer at a nominal spectral resolution of 0.25 cm−1 (unapodised). In addition, the 1600 cm−1 to 2200 cm−1 (6.25 to 4.54μm) spectral region has been measured at 250 K...
متن کاملImproved mid-infrared cross-sections for peroxyacetyl nitrate (PAN) vapour
Absorption spectra of peroxyacetyl nitrate (PAN, CH3C(O)OONO2) vapour at room temperature (295K) have been measured in the mid-infrared range, 550–2200 cm−1 (18.2–4.55μm), using a Fourier Transform infrared spectrometer at instrument resolutions of 0.25 and 0.03 cm−1 (unapodised). Between five and eight measurements were obtained for each spectral band of PAN in the pressure range 0.24–2.20 mb ...
متن کاملFABRICATION OF CARBON FIBERS FROM COMMERCIAL WET SPIN POLYACRYLONITRILE FIBERS
Carbon fibers are fabricated from different materials such as special polyacrylonitrile (PAN) fibers, cellulose fibers and pitch. But PAN fibers are recognized as the most widely used precursor for the present-day manufacture of carbon fibers. The process of fabrication carbon fibers from special PAN fibers is composed of two steps including oxidative stabilization at low temperature and carbon...
متن کاملDifferences between stellar and laboratory reaction cross sections
Nuclear reactions proceed differently in stellar plasmas than in the laboratory due to the thermal effects in the plasma. On one hand, a target nucleus is bombarded by projectiles distributed in energy with a distribution defined by the plasma temperature. The mostly relevant energies are low by nuclear physics standards and thus require an improved description of low-energy properties, such as...
متن کاملLow-temperature rotational relaxation of CO in self-collisions and in collisions with Ne and He.
The low-temperature rotational relaxation of CO in self-collisions and in collisions with the rare-gas atoms Ne and He has been investigated in supersonic expansions with a combination of resonance-enhanced multiphoton ionization (REMPI) spectroscopy and time-of-flight techniques. For the REMPI detection of CO, a novel 2 + 1' scheme has been employed through the A(1)Pi state of CO. From the mea...
متن کامل