[Reliability of corneal thickness measurements by Orbscan II and ultrasound pachymeter].
نویسندگان
چکیده
PURPOSE To access the reliability of corneal thickness measurements by Orbscan II and ultrasound pachymeter. METHODS A retrospective study of 134 eyes from 67 normal subjects between January and June 2001 was obtained. Sex, age, visual acuity, refractive error and corneal thickness measurements by Orbscan II and ultrasound pachymetry were evaluated. All results were analyzed by the paired t test (p<0.05). RESULTS Sixty-seven subjects, 34 (50.7%) female and 33 (49.3%) male, with a mean age of 32.44+/-9.98 were evaluated. The mean of spherical equivalent was -2.68+/-2.62. The mean corneal thickness was 534.81+/-34.45 with the Orbscan II system and 535.00+/-29.53 with the ultrasound pachymeter, values that were not significantly different (p=0.8922). The correlation coefficient between both instruments was 0.8774, and it is effective. CONCLUSIONS Both methods are similar showing good correlation. In this study, the Orbscan II showed reliability, and this tool is extremely useful to evaluate subjects regarding refractive surgery.
منابع مشابه
Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter
Purpose: To compare thickness of central cornea measured using Pentacam, Orbscan II, and ultrasound pachymeter Methods: Patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. Central corneal thickness (CCT) was measured by three metho...
متن کاملCentral and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry.
PURPOSE To compare thickness measurements of the central 6.0 mm of the cornea obtained with the Orbscan(R) II topography system and topographical ultrasound pachymetry. SETTING School of Optometry, University of Santiago de Compostela, Galicia, Spain. METHODS In 24 right eyes, pachymetric measurements were taken at the center and 1.2 mm and 3.0 mm on the superior and inferior hemimeridians....
متن کاملCentral Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy
PURPOSE To determine inter-device agreement for central corneal thickness (CCT) measurement among ultrasound pachymetry, rotating Scheimpflug imaging (Pentacam, Oculus, Wetzlar, Germany), and scanning slit corneal topography (Orbscan II, Bausch & Lomb, Rochester, NY, USA) in highly myopic eyes before and after photorefractive keratectomy (PRK). METHODS This prospective comparative study inclu...
متن کاملCentral and Peripheral Corneal Thickness Measurement in Normal and Keratoconic Eyes Using Three Corneal Pachymeters
PURPOSE To assess the agreement among ultrasonic pachymetry, the Galilei dual Scheimpflug analyzer, and Orbscan II for central and peripheral (Galilei vs. Orbscan) corneal thickness (CCT and PCT) measurement in normal and keratoconic eyes. METHODS In this prospective study, CCT and PCT were measured in 88 eyes of 88 refractive surgery candidates and 128 eyes of 69 keratoconic patients with ul...
متن کاملMeasurements of central corneal thickness using two immersion ultrasound techniques and optical technique.
OBJECTIVE To compare the accuracy of central corneal thickness measurements using ultrasound biomicroscopy, Orbscan II tomography and an Artemis-2 very high frequency ultrasound scanner. METHODS The prospective study was conducted at Eye World Centre, Riyadh, Saudi Arabia, from September to November 2012. One eye from each of 60 normal subjects was analysed. The central corneal thickness was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 68 1 شماره
صفحات -
تاریخ انتشار 2005