Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline

نویسندگان

  • Blanca G Beltrán
  • Luz O Leal
  • Laura Ferrer
  • Víctor Cerdà
چکیده

Hydride generation (HG) of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering species (As, Cr, Cu, and Fe). Different modes of addition of masking agents were accomplished, that is, to either sample or KBH4 reducing solution. The lead determinations were performed using a flow injection analysis (FIA) system coupled to HG and atomic fluorescence spectrometry (AFS). The linearity of calibration curves (1-10 μg Pb L(-1)) was not affected by the addition of the masking agents. The use of KI in the reducing solution diminished interferences from concentrations of As and Cu, while 1,10-phenanthroline showed a positive effect on the interference by As. Moreover, Cr and Cu appeared to be the most serious interfering ions for plumbane (PbH4), because they drastically reduced the analytical signal of lead. Fe did not present any interference under the employed experimental conditions, even at high levels. The accuracy was established through the analysis of certified reference material (i.e., BCR-610, groundwater) using KI as masking agent. The detection limit reached by FIA-HG-AFS proposed methodology was 0.03 μg Pb L(-1).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in natural water samples.

A flow injection on-line sorption preconcentration and separation in a knotted reactor (KR) was coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) for speciation of inorganic arsenic in natural water samples. The method involved on-line formation of the As(III)-pyrrolidinedithiocarbamate (PDC) complex over a sample acidity of 0.001-0.1 mol L(-1) HCl, its adsorption onto the...

متن کامل

Flow injection hydride generation electrothermal atomic absorption spectrometry with in-atomizer trapping for the determination of lead in calcium supplements.

Lead hydride was generated from acid solution, containing potassium ferricyanide as an oxidizing agent, by the reaction with alkaline borohydride solution. The effects of reaction conditions (hydrochloric acid, ferricyanide and borohydride concentrations), and the lengths of reaction and stripping coils were studied. The effects of trapping temperature and argon flow rate were also investigated...

متن کامل

Automated system for on-line determination of dimethylarsinic and inorganic arsenic by hydride generation-atomic fluorescence spectrometry.

A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016