Evaluation of a novel continuous glucose measurement device in patients with diabetes mellitus across the glycemic range.

نویسندگان

  • Linda Morrow
  • Marcus Hompesch
  • Ann M Tideman
  • Jennifer Matson
  • Nancy Dunne
  • Scott Pardo
  • Joan L Parkes
  • Holly C Schachner
  • David A Simmons
چکیده

BACKGROUND This glucose clamp study assessed the performance of an electrochemical continuous glucose monitoring (CGM) system for monitoring levels of interstitial glucose. This novel system does not require use of a trocar or needle for sensor insertion. METHOD Continuous glucose monitoring sensors were inserted subcutaneously into the abdominal tissue of 14 adults with type 1 or type 2 diabetes. Subjects underwent an automated glucose clamp procedure with four consecutive post-steady-state glucose plateau periods (40 min each): (a) hypoglycemic (50 mg/dl), (b) hyperglycemic (250 mg/dl), (c) second hypoglycemic (50 mg/dl), and (d) euglycemic (90 mg/dl). Plasma glucose results obtained with YSI glucose analyzers were used for sensor calibration. Accuracy was assessed retrospectively for plateau periods and transition states, when glucose levels were changing rapidly (approximately 2 mg/dl/min). RESULTS Mean absolute percent difference (APD) was lowest during hypoglycemic plateaus (11.68%, 14.15%) and the euglycemic-to-hypoglycemic transition (14.21%). Mean APD during the hyperglycemic plateau was 17.11%; mean APDs were 18.12% and 19.25% during the hypoglycemic-to-hyperglycemic and hyperglycemic-to-hypoglycemic transitions, respectively. Parkes (consensus) error grid analysis (EGA) and rate EGA of the plateaus and transition periods, respectively, yielded 86.8% and 68.6% accurate results (zone A) and 12.1% and 20.0% benign errors (zone B). Continuous EGA yielded 88.5%, 75.4%, and 79.3% accurate results and 8.3%, 14.3%, and 2.4% benign errors for the euglycemic, hyperglycemic, and hypoglycemic transition periods, respectively. Adverse events were mild and unlikely to be device related. CONCLUSION This novel CGM system was safe and accurate across the clinically relevant glucose range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)

OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...

متن کامل

Evaluation of Glycemic Control in Women with Type 2 Diabetes Mellitus Treated with Ziziphus Fruit

Objective Diabetes mellitus (DM) as a metabolic disorder is becoming a serious threat of health. In recent years, there has been renewed interest in the treatment against different diseases using medicinal plants. The present randomized clinical trial was carried out to evaluate the efficacy of Ziziphus in improving glucose control in women with type 2 diabetes mellitus (T2DM). Materials and...

متن کامل

The effect of low glycemic index foods taken at dinner on blood glucose and insulin levels in patients with type 2 diabetes

Introduction: Diabetes is one of the most common endocrine diseases. With regard to the importance of blood glucose regulation in prevention of diabetic complications, glycemic and insulinemic response determination of foods containing carbohydrates is greatly important. The purpose of the present study, therefore, was to determine the effect of low glycemic index foods taken at dinner on fasti...

متن کامل

بررسی ارتباط بین سطح سرمی C-REACTIVE PROTEIN و هموگلوبین گلیکوزیله در بیماران مبتلا به دیابت نوع 2

Background: Type 2 diabetes mellitus is a common metabolic disorder witht increasing prevalence is increasing worldwide. C-Reactive Protein (CRP) is a marker of systemic inflammation and an independent risk factor for cardiovascular disease (CVD). The aim of this study was to elucidate the correlation between glycemic control and systemic inflammation by measuring serum CRP levels.Methods: In t...

متن کامل

Translating glucose variability metrics into the clinic via Continuous Glucose Monitoring: a Graphical User Interface for Diabetes Evaluation (CGM-GUIDE©).

BACKGROUND Several metrics of glucose variability have been proposed to date, but an integrated approach that provides a complete and consistent assessment of glycemic variation is missing. As a consequence, and because of the tedious coding necessary during quantification, most investigators and clinicians have not yet adopted the use of multiple glucose variability metrics to evaluate glycemi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2011