Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector
نویسندگان
چکیده
BACKGROUND Monte Carlo simulations provide accurate models of nuclear medicine imaging systems as they can properly account for the full physics of photon transport. The accuracy of the model included in the maximum-likelihood-expectation-maximization (ML-EM) reconstruction limits the overall accuracy of the reconstruction results. In this paper, we present a Monte Carlo-based ML-EM reconstruction method for pinhole single-photon emission computed tomography (SPECT) that has been incorporated into the SIMIND Monte Carlo program. The Monte Carlo-based model, which accounts for all of the physical and geometrical characteristics of the camera system, is used in the forward-projection step of the reconstruction, while a simpler model based on ray-tracing is used for back-projection. The aim of this work was to investigate the quantitative accuracy of this combination of forward- and back-projectors in the clinical pinhole camera GE Discovery NM 530c. RESULTS The total activity was estimated in 99mTc-filled spheres with volumes between 0.5 and 16 mL. The total sphere activity was generally overestimated but remained within 10% of the reference activity defined by the phantom preparation. The recovered activity converged towards the reference activity as the number of iterations increased. Furthermore, the recovery of the activity concentrations within the physical boundaries of the spheres increased with increasing sphere volume. Additionally, the Monte Carlo-based reconstruction enabled recovery of the true activity concentration in the myocardium of a cardiac phantom mounted in a torso phantom regardless of whether the torso was empty or water-filled. A qualitative comparison to data reconstructed using the clinical reconstruction algorithm showed that the two methods performed similarly, although the images reconstructed using the clinical software were more uniform due to the incorporation of noise regularization and post-filtration in that reconstruction technique. CONCLUSIONS We developed a Monte Carlo-based reconstruction method for pinhole SPECT and evaluated it using phantom measurements. The combination of a Monte Carlo-based forward-projector and a simplified analytical ray-tracing back-projector produced quantitative images of acceptable image quality. No explicit calibration is necessary in this method since the forward-projector model maintains a relationship between the number of counts and activity.
منابع مشابه
A model based, anatomy dependent method for ultra-fast creation of primary SPECT projections
Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...
متن کاملAttenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study
Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...
متن کاملA three-dimensional ray-driven attenuation, scatter and geometric response correction technique for SPECT in inhomogeneous media.
The qualitative and quantitative accuracy of SPECT images is degraded by physical factors of attenuation, Compton scatter and spatially varying collimator geometric response. This paper presents a 3D ray-tracing technique for modelling attenuation, scatter and geometric response for SPECT imaging in an inhomogeneous attenuating medium. The model is incorporated into a three-dimensional projecto...
متن کاملA model based, anatomy dependent method for ultra-fast creation of primary SPECT projections
Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the effect of body attenuation and i...
متن کاملThe Use of Monte Carlo Simulation in Improving Recon- Struction Quality in Single Photon Emission Computed Tomography
This paper describes an efficient method of generating a model-based system matrix using Monte Carlo simulation for incorporation into reconstruction algorithms for pinhole SPECT imaging and reconstructions. The method is able to model the imaging geometry for pinhole collimators and the detector depth of interaction effect accurately and efficiently, and has demonstrated improvement in the qua...
متن کامل