Personalization of automated peritoneal dialysis treatment using a computer modeling system.
نویسندگان
چکیده
The use of almost standardized dialysis programs--and the absence of any adjustment over time in these program to match the progressive decline in residual kidney function, in addition to the reduction in peritoneal depuration because of the frequency of peritonitis and the use of solutions containing high glucose concentrations--often leads to technique drop-out and transfer to hemodialysis. Our study enrolled 15 clinically stable patients (13 white men, 2 white women; average age: 67.3 +/- 12.99 years; average dialysis vintage: 32.25 +/- 25.10 months) who had been on automated peritoneal dialysis treatment with a standard treatment profile for at least 6 months (dwell time per cycle and solutions fixed at various glucose concentrations in all exchanges). After a peritoneal equilibration test had been performed and clearances (peritoneal and renal) were measured, the dialysis program was modified, individualizing it to the patient ' peritoneal membrane transport by the Twardowski system of classification and taking into account the patient's residual diuresis and need for ultrafiltration. The change was implemented using the Patient on Line software created by Fresenius Medical Care (Bad Homburg, Germany). After a month of personalized dialysis treatment, weekly peritoneal Kt/V in the study group increased significantly (to 1.47 + 0.61 from 1.02 +/- 0.37, p = 0.001); no difference in renal Kt/V was observed. Total Kt/V reached levels of optimum dialysis adequacy (to 2.21 +/- 0.28 from 1.62 +/- 0.33, p = 0.0001). Weekly peritoneal creatinine clearance also increased to 32.86 +/- 16.94 L/1.73 m2 from 22.27 +/- 9.16 L/1.73 m2 (p = 0.005), with renal creatinine clearance essentially stable, and total weekly clearance increasing to 67.58 +/- 14.52 L/1.73 m2 from 53.51 +/- 16.86 L/1.73 m2 (p < 0.0001). The dialysis adequacy improvements obtained involved no statistically significant differences in the total infused volume of dialysis solution, ultrafiltration, or the duration of dialysis treatment. It should also be noted that no changes in residual diuresis occurred.
منابع مشابه
Developing a Device for Automated Peritoneal Dialysis
Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...
متن کاملEffectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study
Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...
متن کاملSupportive treatment of delayed perforated colon due to peritoneal dialysis catheterization
Background: One of uncommon complications in patients with peritoneal catheter is colon rupture which usually occurs during catheter insertion. In this paper, we present a case of delayed perforated colon following insertion of peritoneal catheter. Case presentation: A 37-year-old man was suffering from chronic renal failure (CRF). Nine months after peritoneal catheterization, peritoneal dialy...
متن کاملارایه مدلی جهت پیشبینی بقای بیماران دیالیز صفاقی با استفاده از الگوریتمهای دادهکاوی
Background: Peritoneal dialysis is one of the most commonly used treatment methods for the patients with end stage renal failure. In recent years, the mortality rate of patients under this treatment has decreased; however, long-term survival is still an important challenge for health systems. The present study aimed to predict the survival of continuous ambulatory peritoneal dialysis patients. ...
متن کاملElimination of Abdominal Pain Associated with Automated Peritoneal Dialysis
Thirteen patients have been treated with automated peritoneal dialysis at our center. Of these, three have experienced discomfort with dialysate inflow. They described rectal pain with an intense downward urge to defecate. In two, the sensation was most intense at the onset of the inflow cycle and lessened with each treatment. In both, the sensation disappeared entirely within four weeks. The t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Advances in peritoneal dialysis. Conference on Peritoneal Dialysis
دوره 27 شماره
صفحات -
تاریخ انتشار 2011