Increased strain in the femoral neck following insertion of a resurfacing femoral prosthesis.

نویسندگان

  • T S Wik
  • P O Østbyhaug
  • J Klaksvik
  • A Aamodt
چکیده

The cortical strains on the femoral neck and proximal femur were measured before and after implantation of a resurfacing femoral component in 13 femurs from human cadavers. These were loaded into a hip simulator for single-leg stance and stair-climbing. After resurfacing, the mean tensile strain increased by 15% (95% confidence interval (CI) 6 to 24, p = 0.003) on the lateral femoral neck and the mean compressive strain increased by 11% (95% CI 5 to 17, p = 0.002) on the medial femoral neck during stimulation of single-leg stance. On the proximal femur the deformation pattern remained similar to that of the unoperated femurs. The small increase of strains in the neck area alone would probably not be sufficient to cause fracture of the neck However, with patient-related and surgical factors these strain changes may contribute to the risk of early periprosthetic fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of new concepts in hip arthroplasty.

In this thesis we evaluated two different hip arthroplasty concepts trough in vitro studies and numerical analyses. The cortical strains in the femoral neck area were increased by 10 to 15 % after insertion of a resurfacing femoral component compared to values of the intact femur, shown in an in vitro study on human cadaver femurs. There is an increased risk of femoral neck fracture after hip r...

متن کامل

Performance of the resurfaced hip. Part 1: the influence of the prosthesis size and positioning on the remodelling and fracture of the femoral neck.

Hip resurfacing is an established treatment for osteoarthritis in young active patients. Failure modes include femoral neck fracture and prosthesis loosening, which may be associated with medium-term bone adaptation, including femoral neck narrowing and densification around the prosthesis stem. Finite element modelling was used to indicate the effects of prosthesis sizing and positioning on the...

متن کامل

Femoral Component Positioning in Resurfacing Arthroplasty

Previous studies have suggested that femoral component positioning in resurfacing arthroplasty may affect strains in the femoral neck that could lead to decreased implant longevity, A strain gaged, Sawbones model was used to determine the femoral neck strains for a variety of resurfacing head translations and angulations. We found that head positions affected strain distributions, most position...

متن کامل

Position of hip resurfacing component affects strain and resistance to fracture in the femoral neck.

BACKGROUND Retrieval studies have suggested that the cause of femoral implant failure after metal-on-metal hip resurfacing is multifactorial. Both varus positioning of the femoral component and notching of the superior part of the femoral neck have been associated with femoral component failure. The hypotheses of this study were that placement of a femoral resurfacing component alters femoral n...

متن کامل

Finite element analysis of femoral neck stress in relation to pelvic width.

Hip resurfacing arthroplasty has been developed as an alternative to traditional total hip arthroplasty, in an effort to minimize the loss of native bone in young patients with symptomatic hip osteoarthritis. Femoral neck fracture following hip resurfacing is a unique complication; several risk factors are associated with this complication, including female gender. In the present study, we used...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2010