Measurement of the x-ray mass- attenuation coefficients of gold, derived quantities between 14 keV and 21 keV and determination of the bond lengths of gold
نویسندگان
چکیده
The x-ray mass-attenuation coefficients of gold are measured at 91 energies between 14 keV and 21 keV using synchrotron radiation. The measurements are accurate to between 0.08% and 0.1%. The photoelectric mass-absorption coefficients and the imaginary component of the form factors of gold are also determined. The results include the LI edge and are the most accurate and extensive gold dataset available in this energy range. An analysis of the LI edge XAFS showed excellent agreement between the measured and simulated XAFS and yielded highly accurate values of the bond lengths of gold. When our results are compared with earlier measurements and with predictions of major theoretical tabulations, significant discrepancies are noted. The comparison raises questions about the nature of discrepancies between experimental and theoretical values of mass-attenuation coefficients. (Some figures in this article are in colour only in the electronic version)
منابع مشابه
Radiation attenuation of boron doped clay for 662, 1173 and 1332 keV gamma rays
Background: Radiation shielding properties is an important for a material wish can be used the photon attenuation coefficients of clay produced using different rate of boron have been measured for the purpose of radioactive waste disposal. Materials and Methods: The measurement has been performed using gamma spectrometer contains NaI (Tl) detector at the photon energies of 662, 1173 an...
متن کاملA Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed.Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor.Method...
متن کاملComparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data
Introduction: The advent of dual-modality PET/CT scanners has revolutionized clinical oncology by improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates a noise-free attenuation map (6map). CTAC methods include scaling, s...
متن کاملMeasurement of the x-ray mass attenuation coefficients of gold in the 38–50-keV energy range
We used synchrotron x rays to measure the x-ray mass attenuation coefficients of gold at nine energies from 38 to 50 keV with accuracies of 0.1%. Our results are much more accurate than previous measurements in this energy range. A comparison of our measurements with calculated mass attenuation coefficients shows that our measurements fall almost exactly midway between the XCOM and FFAST calcul...
متن کاملCalculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE
Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010