Analytical and clinical evaluation of two homogeneous assays for LDL-cholesterol in hyperlipidemic patients.

نویسندگان

  • M Esteban-Salán
  • A Guimón-Bardesi
  • J M de La Viuda-Unzueta
  • M N Azcarate-Ania
  • P Pascual-Usandizaga
  • E Amoroto-Del-Río
چکیده

BACKGROUND LDL-cholesterol (LDL-C) concentrations are the primary basis for treatment guidelines established for hyperlipidemic patients. LDL-C concentrations are commonly monitored by means of the Friedewald formula, which provides a relative estimation of LDL-C concentration when the triglyceride concentration is <2000 mg/L and there are no abnormal lipids. The Friedewald formula has several limitations and may not meet the current total error requirement of <12% in LDL-C measurements. METHODS We evaluated the analytical and clinical performance of two direct methods (Roche and Wako) by analyzing 313 fresh serum samples obtained from dyslipidemic patients in a lipid clinic and comparing them with modified beta-quantification. RESULTS Both homogeneous assays displayed excellent precision (CV <2%). The Roche method showed a mean total error of 7.72%, and the Wako method showed a mean total error of 4.46% over a wide range of LDL-C concentrations. The Roche method correlated highly with the modified beta-quantification assay (r = 0.929; y = 1.052x - 168 mg/L; n = 166) and showed a bias of -4. 5% as a result of the assigned standard value. The Wako method also correlated highly with beta-quantification (r = 0.966; y = 0.9125x + 104.8 mg/L; n = 145) without significant bias. The Roche method correctly classified 97% of patients with triglycerides <2000 mg/L, 75% of patients with type IIb hyperlipemia (HPL), and 84% of patients with type IV HPL based on the cutpoints of 1300 and 1600 mg/L, compared with 98%, 78.4%, and 89%, respectively, for the Wako method. In dysbetalipoproteinemic patients, both methods have a 30% mean positive bias compared with beta-quantification. CONCLUSIONS Both direct methods can be a useful alternative when ultracentrifugation is not available for the diagnosis and control of lipid-lowering medication for patients with mixed HPL, but not for patients with type III hyperlipidemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical and clinical performance of a detergent-based homogeneous LDL-cholesterol assay: a multicenter evaluation.

BACKGROUND LDL-cholesterol (LDL-C) concentrations currently are determined in most clinical laboratories using the Friedewald calculation. This approach has several limitations and may not always meet the current total error recommendation in LDL-C measurement of </=12% established by the National Cholesterol Education Program. METHODS In a multicenter study, we evaluated the analytical and c...

متن کامل

Analytical performance and clinical utility of a direct LDL-cholesterol assay in a hyperlipidemic pediatric population.

This study compares a new latex immunoseparation method for the direct determination of plasma low-density lipoprotein cholesterol (LDL-C) with the reference procedure for LDL-C (beta-quantification) in a pediatric hyperlipidemic population. The direct LDL-C assay has a mean bias of -98 mg/L in a fasting group (n = 96) of patients (mean triglycerides 1057 +/- 720 mg/L) and a bias of +177 mg/L i...

متن کامل

Comparative evaluation between chitosan and atorvastatin on serum lipid profile changes in hyperlipidemic cats

The purpose of the present survey was to determine the effects of the chitosan and atorvastatin on serum lipid profile changes and the influence of time on treatment process in cats. For the management of cholesterol induced hyperlipidemia, twenty-one healthy cats were randomly divided into three equal groups. Group A (control) included seven cats that were fed with cholesterol powder (4 g/kg f...

متن کامل

Comparative study of LDL-cholesterol levels in Thai patients by the direct method and using the Friedewald formula.

In this study, low-density lipoprotein cholesterol (LDL-C) levels by direct measurement and estimation using the Friedewald formula, were compared among 1,016 Thai patients. The study assessed blood samples from out-patients sent to the Clinical Chemistry Laboratory, Department of Clinical Pathology, Rajvithi Hospital, Ministry of Public Health, for measurement of total cholesterol (TC), LDL-C,...

متن کامل

Evaluation of two different homogeneous assays for LDL-cholesterol in lipoprotein-X-positive serum.

BACKGROUND The purpose of this study was to evaluate the performance of two homogeneous assays for LDL-cholesterol (LDL-C), a polyethylene/cyclodextrin (PC) assay and a detergent (D) assay, which are based on different principles, in cholestatic serum. METHODS We compared serum LDL-C concentrations determined by the two assays for healthy normolipidemic subjects (n = 42) and cholestatic patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 46 8 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2000