Vascular mapping of the face: B-mode and doppler ultrasonography study
نویسندگان
چکیده
BACKGROUND To analyze the face vascularization pattern using B-mode and Doppler ultrasonography, and also propose an arterial vessel mapping. MATERIAL AND METHODS The investigation was performed on 20 ultrasonography exams of facial vessels through linear and endocavitary transducers. We analyzed and determined the average values for diameters, peak systolic velocity and resistive index of the following arteries: external carotid, lingual, deep lingual, sublingual, facial, submental, inferior labial, superior labial, angular, maxillary inferior alveolar, mental, buccal, greater palatine, infraorbital, superficial temporal, transverse facial and frontal. RESULTS Data was obtained allowing the analysis of the tissue hemodynamics. We were able to map the vascularization of the face and it was possible to access three arteries of small diameter (0,60mm angular artery; 0,55mm greater palatine artery; 0,45mm infraorbital artery). CONCLUSIONS The results presented in this article are valid tool supporting the non-invasive mapping of facial vascularization.
منابع مشابه
Three-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog
Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...
متن کاملEffects of medetomidine on intra-renal arteries resistive and pulsatility indices in clinically normal adult domestic shorthair cats
The aim of this study was to determine the effects of intramuscular injection of medetomidine on intra-renal arteriesresistive and pulsatility indices by duplex Doppler ultrasonographyin clinically normal adult domestic shorthair cats. For this purpose, twenty-six neutered adult healthy domestic shorthair cats (13 females and 13 males) were evaluated. B-mode, color Doppler and pulsed wave Doppl...
متن کاملبررسی مقایسه ای اندازه گیری سریال ارتفاع رحم با اولتراسونوگرافی داپلر در تشخیص عقب ماندگی رشد جنین
Introduction & Objective: There are different methods for detection of fetal growth restriction. The most important methods are serial fondal height (SFH), and ultrasonic measurement. The sensitivities and specifities of those methods are vary among different population, so, in a comparative study, we evaluated the sensitivity and specificity of SFH, a safe and simple method, and Doppler ultr...
متن کاملA Survey Parameters of Hepatic Vessels in Healthy Cats by Color Doppler Ultrasonography
Objective- This survey was accomplished to describe the hepatic artery and portal vein indices in healthy domestic cats by color Doppler ultrasonography technique. Design- Retrospective experimental study. Animals- Twenty domestic short hair (DSH) cats (10 males and 10 females). Procedures- Doppler indices of ...
متن کاملNormal Echocardiographic Findings in Healthy Pigeons
Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...
متن کامل