Age and sex corrected normal reference values of T1, T2 T2* and ECV in healthy subjects at 3T CMR
نویسندگان
چکیده
BACKGROUND Myocardial T1, T2 and T2* imaging techniques become increasingly used in clinical practice. While normal values for T1, T2 and T2* times are well established for 1.5 Tesla (T) cardiovascular magnetic resonance (CMR), data for 3T remain scarce. Therefore we sought to determine normal reference values relative to gender and age and day to day reproducibility for native T1, T2, T2* mapping and extracellular volume (ECV) at 3T in healthy subjects. METHODS After careful exclusion of cardiovascular abnormality, 75 healthy subjects aged 20 to 90 years old (mean 56 ± 19 years, 47% women) underwent left-ventricular T1 (3-(3)-3-(3)-5 MOLLI)), T2 (8 echo- spin echo-imaging) and T2 * (8 echo gradient echo imaging) mapping at 3T CMR (Philips Ingenia 3T and computation of extracellular volume after administration of 0.2 mmol/kg Gadovist). Inter- and intra-observer reproducibility was estimated by intraclass correlation coefficient (ICC). Day to day reproducibility was assessed in 10 other volunteers. RESULTS Mean myocardial T1 at 3T was 1122 ± 57 ms, T2 52 ± 6 ms, T2* 24 ± 5 ms and ECV 26.6 ± 3.2%. T1 (1139 ± 37 vs 1109 ± 73 ms, p < 0.05) and ECV (28 ± 3 vs 25 ± 2%, p < 0.001), but not T2 (53 ± 8 vs 51 ± 4, p = NS) were significantly greater in age matched women than in men. T1 (r = 0.40, p < 0.001) and ECV (r = 0.37, p = 0.001) increased, while T2 decreased significantly (r = -0.25, p < 0.05) with increasing age. T2* was not influenced by either gender or age. Intra and inter-observer reproducibility was high (ICC ranging between 0.81-0.99), and day to day coefficient of variation was low (6.2% for T1, 7% for T2, 11% for T2* and 11.5% for ECV). CONCLUSIONS We provide normal myocardial T2, T2*,T1 and ECV reference values for 3T CMR which are significantly different from those reported at 1.5 Tesla CMR. Myocardial T1 and ECV values are gender and age dependent. Measurement had high inter and intra-observer reproducibility and good day-to-day reproducibility.
منابع مشابه
Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study
BACKGROUND T1 mapping is a robust and highly reproducible application to quantify myocardial relaxation of longitudinal magnetisation. Available T1 mapping methods are presently site and vendor specific, with variable accuracy and precision of T1 values between the systems and sequences. We assessed the transferability of a T1 mapping method and determined the reference values of healthy human ...
متن کاملT1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis
BACKGROUND Myocardial black blood (BB) T2* relaxometry at 1.5T provides robust, reproducible and calibrated non-invasive assessment of cardiac iron burden. In vitro data has shown that like T2*, novel native Modified Look-Locker Inversion recovery (MOLLI) T1 shortens with increasing tissue iron. The relative merits of T1 and T2* are largely unexplored. We compared the established 1.5T BB T2* te...
متن کاملNon-invasive differentiation of idiopathic inflammatory myopathy with cardiac involvement from acute viral myocarditis using cardiovascular magnetic resonance imaging T1 and T2 mapping
BACKGROUND Idiopathic inflammatory myopathy (IIM) is a group of autoimmune diseases with systemic myositis which may involve the myocardium. Cardiac involvement in IIM, although often subclinical, may mimic clinical manifestations of acute viral myocarditis (AVM). Our aim was to investigate the usefulness of the combined analysis of cardiovascular magnetic resonance (CMR) T1 and T2 mapping para...
متن کاملMyocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications
BACKGROUND Myocardial T1 and T2 mapping using cardiovascular magnetic resonance (CMR) are promising to improve tissue characterization and early disease detection. This study aimed at analyzing the feasibility of T1 and T2 mapping at 3 T and providing reference values. METHODS Sixty healthy volunteers (30 males/females, each 20 from 20-39 years, 40-59 years, 60-80 years) underwent left-ventri...
متن کاملT1 and T2 mapping for evaluation of myocardial involvement in patients with ANCA-associated vasculitides
BACKGROUND Myocardial involvement in AAV patients might be silent, presenting with no or nonspecific symptoms, normal ECG, and preserved left-ventricular ejection fraction (LV-EF). Since up to 50% of deaths in these patients may be due to myocardial involvement, a reliable diagnostic tool is warranted. In contrast to LGE-CMR, which has its strengths in detecting focal inflammatory or fibrotic p...