Lactate point-of-care testing for acidosis: Cross-comparison of two devices with routine laboratory results

نویسندگان

  • Remco van Horssen
  • Teska N. Schuurman
  • Monique J.M. de Groot
  • Bernadette S. Jakobs
چکیده

OBJECTIVES Lactate is a major parameter in medical decision making. During labor, it is an indicator for fetal acidosis and immediate intervention. In the Emergency Department (ED), rapid analysis of lactate/blood gas is crucial for optimal patient care. Our objectives were to cross-compare-for the first time-two point-of-care testing (POCT) lactate devices with routine laboratory results using novel tight precision targets and evaluate different lactate cut-off concentrations to predict metabolic acidosis. DESIGN AND METHODS Blood samples from the delivery room (n=66) and from the ED (n=85) were analyzed on two POCT devices, the StatStrip-Lactate (Nova Biomedical) and the iSTAT-1 (CG4+ cassettes, Abbott), and compared to the routine laboratory analyzer (ABL-735, Radiometer). Lactate concentrations were cross-compared between these analyzers. RESULTS The StatStrip correlated well with the ABL-735 (R=0.9737) and with the iSTAT-1 (R=0.9774) for lactate in umbilical cord blood. Lactate concentrations in ED samples measured on the iSTAT-1 and ABL-735 showed a correlation coefficient of R=0.9953. Analytical imprecision was excellent for lactate and pH, while for pO2 and pCO2 the coefficient of variation was relatively high using the iSTAT-1. CONCLUSION Both POCT devices showed adequate analytical performance to measure lactate. The StatStrip can indicate metabolic acidosis in 1 μl blood and will be implemented at the delivery room.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum lactate as a prognostic factor in coronary artery bypass graft operation by on pump method

Background: Lactic acidosis in cardiac surgical patients is a manifestation of systemic inflammation and excess pro-inflammatory cytokine production. This investigation was designed to integrate basic concepts about lactate acidosis with a clinically used of serum lactate in patients under coronary artery bypass surgery (CABG) by on pump method. Methods: From August to September 2012, 15 patie...

متن کامل

Falsely elevated point-of-care lactate measurement after ingestion of ethylene glycol.

BACKGROUND A patient presented with severe acidosis and a point-of-care lactate measurement of 42 mmol/L. Mesenteric ischemia was suspected, with a potential need for laparotomy; however, plasma lactate measurements were below 4 mmol/L. Ethylene glycol ingestion was subsequently diagnosed. We therefore wished to determine why discrepancies in lactate measurements occur and whether this "lactate...

متن کامل

Field effect transistor nanobiosensors: State-of-the-art and key challenges as point of care testing devices

The existing health care systems focus on treating diseases rather than preventing them. Patients are generally not tested unless physiological symptoms are appeared. When they do get tested, the results often take several days and can be inconclusive if the disease is at an early stage. In order to facilitate the diagnostics process and make tests more readily available for patients, the conce...

متن کامل

Longitudinal lactate levels from routine point-of-care monitoring in adult Malawian antiretroviral therapy patients: associations with stavudine toxicities

INTRODUCTION Stavudine is still widely used in under-resourced settings such as Malawi due to its low price. It frequently causes peripheral neuropathy and lipodystrophy and increases the risk of lactic acidosis and other high lactate syndromes. METHODS We studied the association of longitudinal lactate levels, obtained by routine, 3-monthly point-of-care monitoring, with peripheral neuropath...

متن کامل

مقایسه محلول رینگر و رینگر لاکتات به عنوان محلول اولیه گردش خون برون پیکری از نظر ایجاد اسیدوز متابولیک در بیماران کاندید عمل جراحی پیوند عروق کرونر

Background & Aims: Metabolic acidosis can be harmful and can complicate cardiopulmonary bypass (CPB) during coronary artery bypass graft surgery. We hypothesized that the pump prime can cause this disturbance. We compared effects of Ringer solution with Ringer Lactate, two types of priming fluid in producing metabolic acidosis in patients undergoing coronary artery bypass graft (CABG) ...Materi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016