Application of membrane filters for spectrophotometric determination of cationic surfactants in river water and sediment.

نویسندگان

  • S Huij-Feng
  • M Takamori
  • N Hata
  • I Kasahara
  • S Taguchi
چکیده

Cationic surfactant (CS+) in urban river water and sediment was extracted and determined spectrophotometrically with 2 membrane filters. The CS+ in the water samples, mostly in the form of an ion associate with the coexisting anionic surfactant (AS), was collected on a polytetrafluoroethylene (PTFE) membrane filter and eluted with methanol. Bromphenol blue (BPB), hydrochloric acid, and water were added to the methanol solution successively, and the mixed solution was filtered through a mixed cellulose ester membrane filter. The CS+-BPB- ion associate, formed by a counter ion exchange, was collected on the filter and dissolved into N,N-dimethylformamide (DMF) together with the mixed cellulose ester membrane filter. After addition of 2 drops of triethanolamine, the absorbance of the DMF solution was measured. The CS+ in sediment samples was extracted with methanol by ultrasonic irradiation; the methanol solution was then passed through a PTFE membrane filter and evaporated to dryness. The CS+ was redissolved in a small amount of methanol. For water samples, recoveries and relative standard deviations for 0.30 microM benzyldimethyl-tetradecylammonium ion, a standard material, were > or =93 and < or =5%, with a detection limit of 0.02 microM. Concentrations of CS+ in sediments were much higher than those in water samples, indicating that CS+ is adsorbed on the surface of the sediment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Chemometrics in determination of the effects of ionic and non-ionic surfactants on ac-id dissociation constant (pKa) of Meloxicam using spectrophotometric method

The purpose of this study was to determine the acid dissociation constants (pKa) of meloxicam in the presence of various surfactants including sodium lauryl sulfate (SLS) as an anionic surfactant, cetyltrimethylammonium bromide (CTAB) as a cationic surfactant and Triton&reg; TX-100 (TX-100) as a non-ionic surfactant in different pre-determined concentrations. The related pKa was determined spec...

متن کامل

Silver Nanoparticles-Based Nano-drop Spectrophotometric Determination of Cationic Surfactants Coupled with Hydrophobic Interaction; An Application to Pharmaceuticals and Environmental Samples

The proposed work describes the nanodrop spectrophotometric determination of cationic surfactants using citrate-modified silver nanoparticles based on the aggregation of silver nanoparticles induced by cationic surfactants due to the hydrophobic effect. The visible color change in the solution of silver nanoparticle includes a red shift with the quenching of the absorption spectra. The maximum ...

متن کامل

Determination of the Best Model to Estimate Suspended Sediment Load in Zaremrood River, Mazandaran Province

Extended abstract 1- Introduction The phenomena of erosion, sediment transport, and sedimentations have tremendously destructive effects on the environment and hydraulics structures. In general, the sediment transportation depends on river discharges, but the proposed equations inherited serious errors.  The estimation of suspended sediment load (SSL) is one of the most important factors in r...

متن کامل

Application of Differential Kinetic Method Using ANN with a New Synthetic Reagent for Simultaneous Spectrophotometric Determination of Mercury and Palladium

A new selective reagent was used for simultaneous determination of mercury and palladium in real samples with their different kinetic spectrophotometric properties. The method is based on the difference in the rate of the oxidation reaction of the recently synthesized reagent, nitro benzoyl diphenylmethylen phosphorane (N-BDMP), with Hg2+ and Pd2+. The kinetic profiles were monitored and record...

متن کامل

Application of Mixed Micelle-Mediated Extraction for Selective Separation and Spectrophotometric Determination of P-Aminophenol Impurity in Pharmaceutical Formulations

A procedure for separation/preconcentration of para-aminophenol (PAP) in pharmaceutical formulation, based on cloud point extraction (CPE) as a prior step to determination by UV-Vis spectrophotometry has been developed. The analyte reacted with 4-dimethylamino benzaldehyde (DAB) in acidic media to form a shift base, which were separated and preconcentrated in a mixed micelle of the anionic surf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 6  شماره 

صفحات  -

تاریخ انتشار 2001