Automated development of a kinetic method for the continuous-flow determination of creatinine.
نویسندگان
چکیده
A "stopped-flow" method for the kinetic Jaffé determination of creatinine was developed, with the use of a computer-controlled continuous-flow system. Simplex optimization was used to find conditions of hydroxide and picrate giving maximum sensitivity for creatinine. We used a modified central composite experimental design to evaluate creatinine sensitivity and albumin, glucose, and acetone interferences as functions of hydroxide and picrate concentrations. More importantly, this work illustrates that the automated development of clinical chemical methods offers an efficient means of obtaining optimized, well-understood analytical procedures for subsequent routine use in the clinical chemistry laboratory.
منابع مشابه
Spectrophotometric determination of creatinine by monosegmented continuous-flow analysis
A monosegmented continuous-flow system (MCFS) has been evaluated for determination of creatinine in urine using the Jaffé reaction. The analyser is compact and allows 130 determinations to be performed per hour, with a relative standard deviation of the peak height better than 1.5% (N =10). The results for real samples agree with those obtained by. the standard manual Jaffé procedure and with t...
متن کاملRetrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system
Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...
متن کاملEffectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study
Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...
متن کاملContinuous-flow Enzymatic Determination of Creatinine with Improved On-line Removal of Endogenous Ammonia
A new continuous-flow automated enzymatic method suitable for the direct determination of creatinine in physiological samples is described. The proposed system utilizes an on-line gas predialysis unit in conjunction with a flow-through enzyme reactor coil and a potentiometric ammonia detector. The enzyme reactor contains immobilized creatinine iminohydrolase (EC 3.5.4.21) which converts creatin...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 12 شماره
صفحات -
تاریخ انتشار 1978