The new X-ray mapping: X-ray spectrum imaging above 100 kHz output count rate with the silicon drift detector.

نویسنده

  • Dale E Newbury
چکیده

Electron-excited X-ray mapping is a key operational mode of the scanning electron microscope (SEM) equipped with energy dispersive X-ray spectrometry (EDS). The popularity of X-ray mapping persists despite the significant time penalty due to the relatively low output count rates, typically less than 25 kHz, that can be processed with the conventional EDS. The silicon drift detector (SDD) uses the same measurement physics, but modifications to the detector structure permit operation at a factor of 5-10 times higher than conventional EDS for the same resolution. Output count rates as high as 500 kHz can be achieved with 217 eV energy resolution (at MnKalpha). Such extraordinarily high count rates make possible X-ray mapping through the method of X-ray spectrum imaging, in which a complete spectrum is captured at each pixel of the scan. Useful compositional data can be captured in less than 200 s with a pixel density of 160 x 120. Applications to alloy and rock microstructures, ultrapure materials with rare inclusions, and aggregate particles with complex chemistry illustrate new approaches to characterization made practical by high-speed X-ray mapping with the SDD.Note: The Siegbahn notation for characteristic X-rays is commonly used in the field of electron beam X-ray spectrometry and will be used in this article. The equivalent IUPAC notation is indicated in parentheses at the first use. In this article, the following arbitrary definitions will be used when referring to concentration (C) ranges: major: C > 0.1 (10 wt%), minor: 0.01 </= C </= 0.1 (1-10 wt%), and trace: C < 0.01 (1 wt%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Silicon Lithium Detectors for Synchrotron Energy Dispersive X-Ray Fluorescence Spectroscopy

Introduction Detector description and its principle of operation Detector module. Detector Features and its Performance EDXRF of Fe 55 Spectrum Detector comparison with Silicon Drift Detector SDD Concluding remarks References A Silicon Lithium Si(Li) detector is presented. The detector structure and its working principle are explained. The detector is cooled to 77o K by liquid Nitrogen. The det...

متن کامل

Vortextm – a New High Performance Silicon Drift Detector for Xrd and Xrf Applications

A new class of silicon drift detectors (SDD), called “VortexTM”, with a large active area (~ 0.5 cm), high-energy resolution (<150 eV FWHM) and high-count rate capability (>1 Mcps) has been developed for X-ray diffraction (XRD) and X-ray fluorescence (XRF) applications. The VortexTM design allows for a relatively large active area while still maintaining a very low anode capacitance (~ 60 fF). ...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 2006