Prospective study of the Acri.LISA bifocal intraocular lens.
نویسندگان
چکیده
PURPOSE To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG). SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined. RESULTS At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 logMAR and the mean binocular best distance-corrected near acuity, 0.012 +/- 0.0084 logMAR (both approximately 20/20). The mean binocular best distance-corrected intermediate acuity changed significantly as a function of the distance of the test, from 0.012 +/- 0.084 logMAR (approximately 20/20) at 33 cm to 0.265 +/- 0.099 logMAR (approximately 20/40) at 70 cm (P<.01). Contrast sensitivity was within normal limits under photopic and mesopic conditions. Binocular contrast sensitivity was statistically significantly better than monocular contrast sensitivity at all spatial frequencies under both illumination levels (P<.01). CONCLUSION The Acri.LISA 366D IOL provided a satisfactory full range of vision; a high level of uncorrected and corrected distance, intermediate, and near acuity; and improved contrast sensitivity under photopic and mesopic conditions.
منابع مشابه
Bi- and Multifocal Intraocular Lenses
The present paper presents a review of multifocal intraocular lenses (IOLs) focusing on the optical principle used to create multifocality: refraction and diffraction. The principal optics of the different IOL designs in the market were discussed and compared. The main conclusion of this study states that diffractive bifocal optics seems to be superior to refractive designs which is well-substa...
متن کاملComparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench.
PURPOSE To assess the differences in optical performance of 9 multifocal IOLs using the same optical bench and to propose a possible comparison for surgeons. SETTING Rothschild Foundation, Paris, France. DESIGN Experimental study. METHODS Nine IOLs (Acrysof Restor +3.0 diopter [D] SN6AD1, Acrysof Restor +4.0 D SN60D3, Acrysof aspheric monofocal SN60WF, Acri.Lisa 366D, Finevision Micro F, ...
متن کاملComparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens.
PURPOSE The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient's visual function 3 months after implantation. PATIENTS AND METHODS This is a randomized prospective study involving bilateral implantation of a trifoc...
متن کاملTheoretical and practical performance of a concentric bifocal intraocular implant lens
Some results from a survey of 43 patients who had a monofocal intra-ocular-lens (IOL) in one eye and a concentric bifocal intra-ocular-lens in the fellow eye are reported. Twenty patients with 6/9 or better post-operative visual acuity in both eyes, participated in the main part of the study. Optical transfer functions for the bifocal lens showed that, compared to an optimal single-vision corre...
متن کاملClinical comparison of patient outcomes following implantation of trifocal or bifocal intraocular lenses: a systematic review and meta-analysis
To assess the visual effects of trifocal intraocular lenses (IOLs) compared to bifocal IOLs in cataract surgery, a meta-analysis of prospective comparative clinical trials (including 4 randomized controlled trials and 4 cohorts) was conducted. The defocus curves showed a better distance-corrected intermediate visual acuity (VA) for the trifocal group (MD -0.07; 95% CI, -0.10 to -0.05; p < 0.000...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 33 11 شماره
صفحات -
تاریخ انتشار 2007