To derotate or not? The impact of a permanent derotation screw on the revision rate of dynamic hip screw fixation for

نویسندگان

  • Martyn J Parker
  • Raju Karuppal
چکیده

In this retrospective study, we examine the impact that Background employing a permanent derotation screw (DRS) has on the rate of revision for 2-hole dynamic hip screws (DHS, a.k.a. sliding hip screws), used for internal fixation of intracapsular neck of femur (NOF) fractures. To the best of our knowledge, we are the first to examine the impact of using a derotation screw on DHS revision rate. : We obtained a list of 64 patients suffering intracapsular NOF fracture Methods treated with 2-hole DHS over a 5-year period, 28 of these were also treated with a DRS, forming our DRS group, 36 were not (non-DRS group). Fracture severity and patient demographics between the groups were compared to ensure homogeneity. The rate of revision to arthroplasty (total or hemi) of the two groups were compared. : The mean age in the DRS group was 70.79 years, 1.77 years lower Results than the non-DRS group (p=0.570). The DRS group had a rate of revision of 14%, in comparison with 39% in the non-DRS group (p=0.0299), corresponding with a number needed to treat of 4.06 derotation screws to prevent a single failure. : In this study, employing a permanent derotation screw alongside Conclusions a 2-hole DHS was associated with a significantly lower rate of revision to arthroplasty than using a 2-hole DHS alone. We would recommend this be further investigated with prospective randomized trials, to provide robust evidence and make clinical recommendations. 1 1 2 3

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

To derotate or not? The impact of a permanent derotation screw on the revision rate of dynamic hip screw fixation for

In this retrospective study, we examine the impact that Background employing a permanent derotation screw (DRS) has on the rate of revision for 2-hole dynamic hip screws (DHS, a.k.a. sliding hip screws), used for internal fixation of intracapsular neck of femur (NOF) fractures. To the best of our knowledge, we are the first to examine the impact of using a derotation screw on DHS revision rate....

متن کامل

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

بررسی کاربرد Short barrel DHS در درمان شکستگی انترتروکانتریک

Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...