Two-dimensional silicon vidicon astronomical photometer.

نویسندگان

  • T B McCord
  • J A Westphal
چکیده

We have developed and successfully used an integrating two-dimensional silicon diode array vidicon photometer which is exceptionally well suited for use with telescopes. The video signal is read out from the 1-cm silicon target of the vidicon through a current mode preamplifier and then converted to digital form and stored on magnetic tape. The 256 x 256 element frames are recorded at 20,000 eight-bit words/sec. The vidicon tube has a published quantum efficiency ranging from 85% at 0.5 micro to 6% at 1.1 micro and must be cooled to about -65 degrees C to eliminate thermal dark current. The minimum detectable signal in the present system is about 1000 carriers per resolution element, limited by preamplifier and other system noise. The system is used as a single-frame camera. The large dynamic range (>10(3)), linear response, high quantum efficiency over a large spectral region, and low cost of the system make it well suited for digital direct image and spectroscopy as well as for a laboratory digitizer of two-dimensional m terial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a vidicon spectrometer for simultaneous flame-emission analysis for sodium and potassium in serum.

We describe a unique new approach to analytical spectroscopy, which makes use of a silicon-target vidicon tube to rapidly and repetitively scan ultraviolet and visible spectra. We discuss the concept and characteristics of the vidicon spectrometer and illustrate its application to simultaneousdeterminationof sodium and potassium In serum by flame photometry. Average values of coefficients of va...

متن کامل

ar X iv : a st ro - p h / 96 07 10 7 v 1 2 2 Ju l 1 99 6 An SSPM - Based High - Speed Near - Infrared Photometer for Astronomy

Received ; accepted – 2 – ABSTRACT We describe the design, operation, and performance of a new high-speed infrared photometer using the Solid-State Photomultiplier (SSPM) detector. single-photon counting capability over the 0.4-28 micron wavelength range, intrinsic time response of order 1 ns, and low detector noise (Petroff, et al., 1987). We have operated a 200x200-micron back-illuminated SSP...

متن کامل

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil)

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil) Dr. M. Sabouhi* - Dr. M. Dakhilalian** - Dr. N. Nehchiri*** *- Assistant Professor of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Member of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Scienc...

متن کامل

In-flight calibration of the Herschel-SPIRE instrument*

SPIRE, the Spectral and Photometric Imaging REceiver, is the Herschel Space Observatory’s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier-transform spectrometer (FTS) covering 194−671 μm (447−1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrume...

متن کامل

Application of a vidicon spectrometer for simultaneous multicomponent drug determinations.

A rapid scanning vidicon spectrometer has been evaluated for the simultaneous determination of drugs in mixtures, without a separation step. Spectral data in the ultraviolet region are collected on-line with a small computer at repetition rates of 100 scans per second. Absorbance data at several wavelengths are processed by matrix equations to resolve them into the concentration of each compone...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 1972