Measurement of the 4Pkonfocal point spread function prow& 75 nm axial resolution

نویسندگان

  • S. W. Hell
  • H. K. Stelzer
چکیده

In a 4Pi-confocal microscope the specimen is illuminated and observed coherently from above and below such that the numerical aperture is increased [S. W. Hell, European Patent Application 91121368.4 (filed 1990, published 1992), S. W. Hell and E. H. K. Stelzer, J. Opt. Sot. Am. A9,2159 (.1992)]. The point spread functions of 4Pi-confocal and confocal microscopes were measured. Our measurements prove a threeto seven-fold increase of axial resolution, thus opening the prospect for a powerful three-dimensional imaging technique with an axial resolution down to 75 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corkscrew point spread function for far-field three-dimensional nanoscale localization of pointlike objects.

We describe the corkscrew point spread function (PSF), which can localize objects in three dimensions throughout a 3.2 μm depth of field with nanometer precision. The corkscrew PSF rotates as a function of the axial (z) position of an emitter. Fisher information calculations show that the corkscrew PSF can achieve nanometer localization precision with limited numbers of photons. We demonstrate ...

متن کامل

Mirror-enhanced super-resolution microscopy

Axial excitation confinement beyond the diffraction limit is crucial to the development of next-generation, super-resolution microscopy. STimulated Emission Depletion (STED) nanoscopy offers lateral super-resolution using a donut-beam depletion, but its axial resolution is still over 500 nm. Total internal reflection fluorescence microscopy is widely used for single-molecule localization, but i...

متن کامل

Improved axial resolution by point-spread autocorrelation function imaging.

Based on an interferometric spatial autocorrelation of two shifted point-spread functions combined with confocal detection, we demonstrate that the point-spread autocorrelation function technique provides improved axial resolution compared with conventional confocal imaging. The principle of the technique is demonstrated for a one-sided f luorescing step object.

متن کامل

Spectral shaping to improve the point spread function in optical coherence tomography.

We demonstrate inhibition of the sidelobes of the axial point spread function in optical coherence tomography by shaping the power spectrum of the light source with a remaining power of 4.54 mW. A broadband amplified spontaneous emission source radiating at 1565 +/- 40 nm is employed in a free-space optical coherence tomography system. The axial point spread functions before and after optical s...

متن کامل

Image formation and data acquisition in a stage scanning 4Pi confocal fluorescence microscope.

We describe the three-dimensional (3-D) image formation and data acquisition in a stage scanning 4Pi confocal fluorescence microscope with the use of two-photon excitation. The 3-D point-spread functions of the 4Pi confocal and regular confocal microscope are measured and compared. Particular emphasis is given to the data acquisition procedure. 4Pi confocal microscopy results in a point-spread ...

متن کامل