Left ventricular functional assessment in murine models of ischemic and dilated cardiomyopathy using [18 F]FDG-PET: comparison with cardiac MRI and monitoring erythropoietin therapy

نویسندگان

  • Stefan Brunner
  • Andrei Todica
  • Guido Böning
  • Stefan G Nekolla
  • Moritz Wildgruber
  • Sebastian Lehner
  • Martina Sauter
  • Christopher Übleis
  • Karin Klingel
  • Paul Cumming
  • Wolfgang Michael Franz
  • Marcus Hacker
چکیده

BACKGROUND We performed an initial evaluation of non-invasive ECG-gated [18 F]FDG-positron emission tomography (FDG-PET) for serial measurements of left ventricular volumes and function in murine models of dilated (DCM) and ischemic cardiomyopathy (ICM), and then tested the effect of erythropoietin (EPO) treatment on DCM mice in a preliminary FDG-PET therapy monitoring study. METHODS Mice developed DCM 8 weeks after injection with Coxsackievirus B3 (CVB3), whereas ICM was induced by ligation of the left anterior descending artery. LV volumes (EDV and ESV) and the ejection fraction (LVEF) of DCM, ICM and healthy control mice were measured by FDG-PET and compared with reference standard results obtained with 1.5 T magnetic resonance imaging (MRI). In the subsequent monitoring study, LVEF of DCM mice was evaluated by FDG-PET at baseline, and after 4 weeks of treatment, with EPO or saline. RESULTS LV volumes and the LVEF as measured by FDG-PET correlated significantly with the MRI results. These correlations were higher in healthy and DCM mice than in ICM mice, in which LVEF measurements were somewhat compromised by absence of FDG uptake in the area of infarction. LV volumes (EDV and ESV) were systematically underestimated by FDG-PET, with net bias such that LVEF measurements in both models of heart disease exceeded by 15% to 20% results obtained by MRI. In our subsequent monitoring study of DCM mice, we found a significant decrease of LVEF in the EPO group, but not in the saline-treated mice. Moreover, LVEF in the EPO and saline mice significantly correlated with histological scores of fibrosis. CONCLUSIONS LVEF estimated by ECG-gated FDG-PET significantly correlated with the reference standard MRI, most notably in healthy mice and mice with DCM. FDG-PET served for longitudinal monitoring of effects of EPO treatment in DCM mice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria.  Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...

متن کامل

Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI

PURPOSE Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare gated F-18 FDG PET and cardiac MRI for the assessment of ventricular volume and ejection fraction (EF) in patients with HF. METHODS Eighty...

متن کامل

Monitoring left ventricular dilation in mice with PET.

UNLABELLED Molecular imaging by small-animal PET is an important noninvasive means to phenotype transgenic mouse models in vivo. When investigating pathologies of the left ventricular (LV) myocardium, the serial assessment of LV volumes is important. By this, the presence of LV dilation as a sign of developing heart failure can be detected. Whereas PET is usually used to derive biochemical and ...

متن کامل

Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients

  Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...

متن کامل

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012